Start signal
Command
Length
Bond_ID
CS
0x02
0x0E
2 Bytes
0 or 2 Bytes
1 Byte
Response (
Start signal
Command | 0x40
Length
Status
CS
0x02
0x4E
0x01 0x00
1 Byte
1 Byte
Status:
0x00:
Request successfully processed
0x01:
Operation failed (e.g. Bond_ID not found)
0xFF:
Operation not permitted
7.1.9.1. Example 1
Request to remove all bonding data.
Start signal
Command
Length
CS
0x02
0x0E
0x00 0x00
0x0C
Response:
Start signal
Command | 0x40
Length
Status
CS
0x02
0x4E
0x01 0x00
0x00
0x4D
Successfully removed all bonding information.
7.1.9.2. Example 2
Request to remove the bonding of the device corresponding to Bond_ID 0.
Start signal
Command
Length
Bond_ID
CS
0x02
0x0E
0x02 0x00
0x00 0x00
0x0E
Response:
Start signal
Command | 0x40
Length
Status
CS
0x02
0x4E
0x01 0x00
0x00
0x4D
Successfully removed the bonding information.
7.1.10. CMD_ALLOWUNBONDEDCONNECTIONS_REQ
In case the
SECFLAGS_BONDEDCONNECTIONSONLY_ENABLE
bit has been set in the
user setting, this command temporarily allows the connection setup of unbonded devices
until the radio module is reset.
Format:
Proteus-e reference manual version 0.3
© November 2021
www.we-online.com/wireless-connectivity
43