Resistance measurement
Measuring
range
Resolution
Accuracy
600 Ω
0.1 Ω
± (1.2 % + 2 digits)
6 kΩ
0.001 kΩ
60 kΩ
0.01 kΩ
600 kΩ
0.1 kΩ
6 MΩ
0.001 MΩ
60 MΩ
0.1 mΩ
± (2.0 % + 5 digits)
Open circuit voltage: 0.4 V
Overload protection: 250 V DC or 250 V AC RMS.
Acoustic continuity check
Measuring
range
Resolution
Accuracy
Buzzer
0.1 Ω
The integral signal
generator sounds up
to 30 ohms
Open circuit voltage: ~1.2 V
Overload protection: 250 V DC or 250 V AC RMS
Diode test
Measuring
range
Resolu-
tion
Accuracy
Diode
0.001 V
Indicates the diode test
voltage
Test current:
∼
1 mA DC
Test voltage:
∼
3.3 V DC
Overload protection: 250 V DC or 250 V AC RMS.
Capacitance measurement
Measuring
range
Resolu-
tion
Accuracy
6 μF
0.001 μF
< 2 μF ± (4.0 % + 5
digits)
± (4.0 % + 3 digits)
60 μF
0.01 μF
600 μF
0.1 μF
6 mF
1 μF
60 mF
10 μF
Overload protection: 250 V DC or AC RMS
SEL button
[11]
Used for zeroing DC current measurements (
ZERO
in
the display).
Moreover used to switch between various functions,
e.g. Ω, continuity.
A brief beep confirms pressing of the button.
MIN/MAX button
[10]
■
Press the MIN/MAX
button once or more to dis
-
play the maximum or minimum measured value
as a value or the difference between the two.
RAN button
[9]
■
Press the RAN
button to switch between auto-
range and manual range switching.
Hz/% button
(in the A or V measuring range)
[5]
To switch between Hz and duty cycle measurement.
The
duty cycle
equals, for a square wave signal, the
ratio of the length of the switched on state (pulse
duration) to the period duration (pulse width mod
-
ulation). The duty cycle is specified as a dimension
-
less ratio with a value between 0 and 1, or 0 and
100 %.
B.L. / HOLD button
[4]
■
Press the B.L./HOLD
button to freeze the cur-
rently displayed value.
3
Press and hold the
B.L./HOLD
button to switch
on the backlight.
3
If set in the measuring range, the measuring point
illumination is also switched on.
Transducer clamp jaws
1
Record the current flowing through the cable.
■
Note the markings
+
and
-
on the current jaws,
to determine the current direction (direct current
measurement only).
■
Open the clamp jaws.
■
Enclose a cable.
■
Ensure the jaws close correctly.
■
There must not be any foreign bodies in the
connecting gap.
Connections
Input
[6]
:
Input for the red test lead for voltage,
resistance and continuity measurements.
COM
[7]
:
Common input for the black test lead for
voltage, resistance and continuity measurements.
If the set value is exceeded over a long period by
the steady current being measured, heating can
occur, which can impair the operating and functional
safety of internal circuits.