Cold location controller for top-hat rail installation with enhanced operating modes for 4 cold locations

CRC-BL_V2.4.0_PI_2021-02_DE

3

Subject to technical changes

CRC-BL

Version and validity of the documentation

Any versions not listed are special solutions for individual projects and are not described in detail in this document.
This document automatically ceases to be valid if a new technical description is issued.

Manufacturer: 

Wurm GmbH & Co. KG Elektronische Systeme, Morsbachtalstraße 30, D-42857 Remscheid

You can find more information on our website at 

www.wurm.de

.

1.4 

Connection diagram

Fig. 2: Connection diagram

Version

Date

V2.4.0 

and higher

2021-02

Documentation status

Pos.

Designation

Function

1

C-BUS interface

Data communication (H = CAN high, S = shield, 

L = CAN low)

2

Output relays K1...K4

Dependent on cold location type, floating contact, 

230V~, 4(2)A

3

Power supply L

230V~/50Hz

4

Power supply N

Neutral conductor

5

Digital inputs Di1...Di4

Dependent on cold location type

6

Defrost bus

Defrost synchronisation

7

Sensor inputs S1...S4

Temperature sensor

12 13 14 15 16 17 18

11

22 23 24 25 26 27 28 29

21

38 37 36 35 34 33 32 31

39

4 3 2 1

12 13 14 15 16 17 18

11

22 23 24 25 26 27 28 29

21

38 37 36 35 34 33 32 31

39

CRC-BL

Frigoentry Blueline

2sec.

d

c

1

2

4

6

3

5

7

S2

S3

S4

S1

GND

Di2

Sync.

Di3

N

Di1

Di4

K1

K2

K3

K4

H

0V

S

L

Содержание CRC-BL

Страница 1: ...r defrost hot gas defrost and cool gas defrost Defrost control by real time clock with power reserve Simple defrost synchronisation of multiple controllers master slave 8 defrost times by integrated weekly timer Digital inputs for setpoint switchover manual defrost initiation and door contact Option to select 3 point control Control sensor weighting can be set separately for day operation and nigh...

Страница 2: ...or purposes other than the intended purpose WARNUNG DANGER TO LIFE FROM ELECTRIC SHOCK AND OR FIRE Switch off the power to the entire plant when carrying out installation wiring or removal work Otherwise a mains voltage and or external voltage may still be present even if the control voltage is switched off Always remove both power plugs L and N The wiring of the device must be carried out only by...

Страница 3: ... wurm de 1 4 Connection diagram Fig 2 Connection diagram Version Date V2 4 0 and higher 2021 02 Documentation status Pos Designation Function 1 C BUS interface Data communication H CAN high S shield L CAN low 2 Output relays K1 K4 Dependent on cold location type floating contact 230V 4 2 A 3 Power supply L 230V 50Hz 4 Power supply N Neutral conductor 5 Digital inputs Di1 Di4 Dependent on cold loca...

Страница 4: ...p hat rail 2 B Push the device downwards onto the top hat rail The device snaps into place with the fastening safety catch a on the top hat rail You can now connect the device Fig 3 Top hat rail installation 1 6 Technical data Power supply 230V 10 15 max 8VA Display 1 x display with plain text display 2 x green LED C BUS data traffic CAN Tx CAN Rx C BUS communication 3 conductor CAN bus interface ...

Отзывы: