background image

Würges Vibrationstechnik GmbH 

Daimlerstraße 9
D-86356 Neusäß
Telephone   +49  8 21  99 98 24-00
Telefax   

+49  8 21  99 98 24-10

E-Mail  

[email protected]

Web www.wuerges.de 

(Translation of the Original Instruction Manual)

Installation and Operating Instructions

Magnetic Vibrator MR 1

Содержание MR 1

Страница 1: ...aimlerstraße 9 D 86356 Neusäß Telephone 49 821 999824 00 Telefax 49 821 999824 10 E Mail info wuerges de Web www wuerges de Translation of the Original Instruction Manual Installation and Operating Instructions Magnetic Vibrator MR 1 ...

Страница 2: ...ons 4 Technical Data Page 7 5 Transport and Storage Page 8 6 Installation and Startup Page 9 6 1 Assembly Installation 6 2 Electrical connection Cable connection 6 3 Intensity adjustment 7 Servicing and Maintenance Page 13 8 Spare Parts Page 14 9 Disposal and Recycling Page 16 10 Warranty Page 16 Appendix Page 17 EU Declaration of Conformity Contents ...

Страница 3: ...l tage Directive 2014 35 EU The Operating Instructions have to be read and understood by every person at the user s company who is assigned with assembly setting up start up the maintenance and repair of vibration motors This also applies for additional instructions in case of modified devices The instruction manual must be read carefully and in full before using the vibrator motors 1 General Info...

Страница 4: ... possibility of fatal severe or irreversible injuries caused by live parts WARNING Refers to the possibility of fatal severe or irreversible injuries caused by general hazards HOT SURFACE Refers to the possibility of severe or irrevers ible injuries caused by touching hot surfaces DISCONNECT Refers to the fact that the motor must be MOTOR FROM MAINS disconnected from the electricity mains and secu...

Страница 5: ...d sort or grade Any other use is deemed to be not as inten ded or misuse Electric vibrators are designed to generate forces that can be destructive The vibrating machine must be designed for the forces generated by the electric vibrators The operator shall bear responsibility for the operation of vibration motors in explosion hazardous areas 3 2 Skilled personnel qualifications The installation as...

Страница 6: ...l injuries Electric vibrators must be safely disconnected from the electricity mains before any work is carried out on them The required procedure is as follows 1 Switch off vibrator motor 2 Secure against being switched back on again 3 Test for safe disconnection from the power supply 4 Allow the vibrator motor to cool Do not touch the vibrator motors while they are running or soon after switchin...

Страница 7: ...ype designation 2 Mains voltage 3 Speed 4 Thermal insulation class Y 80 C 5 Serial number 6 IP protection 7 Mains frequency 8 Year built 9 Power input 10 Nominal current Please see our catalogue for additional technical dara ...

Страница 8: ...returned to the manu facturer for repair Until they are installed the magnetic vibrators should be stored in enclosed dry rooms at a max ambient temperature of 40 C Vibrators must always be stood on their bases or footings Do not stack vibrator motors Do not lift up the vibrator by its installed connection cable Note and follow the local accident prevention regulations 5 Transport and Storage ...

Страница 9: ...y class 6 8 8 EN ISO 4032 DIN934 may be used The bolts must be secured against mechani cal loosening by Schnorr washers type VS Nord Lock washers or RIPP LOCK washers The fixing bolts must be checked for secure fit after approx two operating hours and if necessary retightened Other checks should be carried out daily Improper fixing results in the breakage of the feet of the magnetic vibrator 6 Ins...

Страница 10: ... in accordance with EN 60204 1 The mains voltage and frequency must corre spond to the nameplate data The motor must 1 Switch off vibrator motor and secure against being switched back on again 2 Check for safe isolation from supply 3 Allow the motor to cool only be connected to an electricity system that conforms to the VDE provisions Each motor must have its own upstream motor protection device a...

Страница 11: ...place not strain relieved and not waterproof Carefully close the vibrator with seal and screw lock The motor connection line has to be securely fastened approx 0 5m after leaving the motor The first line attachment point and the motor shall not be moveable against each other The connecting cable has to be laid in such a way that natural vibrations are being avoided and there will be no tensile loa...

Страница 12: ... is adjusted using pluggable brass spacer plates Pos 14 and 15 With both nuts Pos 7 unscrewed the air gap can be change can be changed by removing or adding spacer plates between rubber pad Pos 13 and rotor Pos 3 Both sides need to be adjusted equally The required spacer plates are stocked bet ween the ballast discs Pos 11 Noise generated by wrong adjustment The rotor thuds onto the magnet with to...

Страница 13: ...13 Maintenance is not necessary since there are no wear parts 7 Maintenance and Repair ...

Страница 14: ...We expressly point out that original spare parts and accessories that were not supplied by us have not been tested and released by us Therefore installation and or deployment of such products may possibly change given design characteristics to produce negative effects thus posing an active and or passive risk to safety Würges excludes any liability and warranty in cases where damage arises by usin...

Страница 15: ...rts list MR 1 No Order No Pieces 1 05501 1 2 05601 1 3 05701 1 4 21601 2 5 22301 4 6 22501 2 7 28201 2 9 29491 1 No Order No Pieces 10 62101 1 11 75351 32 12 75831 1 13 76201 2 14 76501 0 5 mm 8 15 76511 0 2 mm 8 ...

Страница 16: ...ecycling Würges provides warranty for 1 year be ginning with delivery for all new magnetic vibrator Warranty expires when the motor is connected wrong or connec ted with wrong voltage the motor fails because of missing or wrong electric protection there were changes made to the motor the motor was damaged during transport the motor was not installed as shown in chapter 6 the motor was connected wi...

Страница 17: ...turer will electronically transmit the specific documents to national bodies on request The designated product is to be seen as a component for installation into a machine or system Commissioning is prohibited until the conformity of the final product to the directive 2006 42 EC is established The safety instructions of the product documentation must be duly observed This declaration of conformity...

Страница 18: ...18 Notes ...

Страница 19: ...19 Notes ...

Страница 20: ...20 Würges Vibrationstechnik GmbH Daimlerstraße 9 D 86356 Neusäß Telephone 49 821 999824 00 Telefax 49 821 999824 10 E Mail info wuerges de Web www wuerges de 06 2017 ...

Отзывы: