6.1. Assembly/Installation
Magnetic vibrators can be installed in any in-
stallation position. Vibrators may only be built
on to machines with flat, oil, grease and paint-
free and flexurally rigid mounting surfaces.
Surface quality:
Only bolts in quality class 8.8 > EN ISO 4014
(DIN 931); EN ISO 4017 (DIN 933) and nuts
in quality class 6 > 8.8 EN ISO 4032 (DIN934)
may be used.
The bolts must be secured against mechani-
cal loosening by Schnorr washers, type VS,
Nord-Lock washers or RIPP LOCK
®
washers.
The fixing bolts must be checked
for secure fit after approx. two
operating hours and if necessary
retightened. Other checks should
be carried out daily!
Improper fixing results in the
breakage of the feet of the
magnetic vibrator.
6. Installation and Startup
Minimum tightening torque
M 8
30 Nm
Mounting plate
Vibrator foot/flange
correct
correct
incorrect
✓
✓