11
Use only a flexible cable for connection.
We recommend the following cable type:
H 07 RN-F 3G1,5
Plastic cable is unsuitable.
Fit cable end sleeves onto cable ends. In no
case solder on since the stranded wires might
break near the solder joint.
Insert cable into the vibrator and connect it acc.
to the circuit diagram above. (See page 10).
When tightening the union nut screw connecti-
on make sure that the cable sheath still is fully
covered by the seal. If this is not followed, the
cable is not clamped in place, not strain relieved
and not waterproof.
Carefully close the vibrator with seal and screw
lock.
The motor connection line has to be securely
fastened approx. 0.5m after leaving the motor.
The first line attachment point and the motor
shall not be moveable against each other. The
connecting cable has to be laid in such a way
that natural vibrations are being avoided and
there will be no tensile load.
Check the current input when the motor is ope-
rated for the first time. It should be greater than
the value stated on the type plate, remedy the
situation by decreasing the centrifugal force
(see Chapter 7).
Check the line for chafe marks from time to
time and eliminate the cause for this where
applicable.