background image

Installation Steps

Step 1: Separate [Base of Main Body] & [Base of Magnetic 

Part] from their respective main body as per below illustration.

5

 Main Body  

Base of Main Body 

Main Body of 

Magnetic Part  

Base of Magnetic 

Part 

Содержание WL-ZSPDBPW-MT-01

Страница 1: ...Smart Contact Sensor FOR WL ZSPDBPW MT 01 User Manual Nanjing IOT Sensor Technology Co Ltd Publication Number 2015 0407 V01 ...

Страница 2: ...e harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of thefollowing measures Reorient or relocate...

Страница 3: ...ns 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Federal Communications Commission FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment In order to avoid the possibility of exceeding the FCC radio frequency...

Страница 4: ...Sensor Technology Co Ltd hereinafter referred to as Wulian This product shall be used with smart home APP as well as the supplied accessories Wulian is not responsible for any loss due to improper installation and usage of this product Please check the Wulian website periodically for manual and APP update availability and the relevance Without the written permission of Wulian any individuals and e...

Страница 5: ...ur other devices Alarm with wireless transmission brings about rapid response high anti interference and low rate of false alarm Low consumption energy saving and environment friendly for building green human living environment Wireless device with small size is for hiding and merging with home environment perfectly Made of high shock resistance and temperature resistance material shell is sturdy ...

Страница 6: ... Temperature Operating Humidity PCB Antenna DC 3V CR2 1 4uA 20mm Window Mounted PC White 55 UL94 V 2 10 45 95 RH Noncondensing IEEE 802 15 4 ZigBee SmartRoom Communication Protocol Main Body 23 19 60 Magnetic Part 10 19 60 Notes This product supports gateway with LAN 2 Current For Opening Closing Door 2uA at opening door 4uA at Closing Door Overall Dimension L x W x H mm ...

Страница 7: ...st Manual 1 Manual Battery 1 Guarantee Card PE Form Tape 2 3 Main Body Base Of Main Body 1 Magnetic Part Base of Magnetic Part 1 Flat Cross Recessed Self Tapping Screw with Pointed Tail ST3 12 4 Guarantee Card 1 ...

Страница 8: ...Function Illustration 4 Main Body Base of Main Body Battery Compartment SET Key System Indicator Main Body Of Magnetic Part Base Of Magnetic Part ...

Страница 9: ...llation Steps Step 1 Separate Base of Main Body Base of Magnetic Part from their respective main body as per below illustration 5 Main Body Base of Main Body Main Body of Magnetic Part Base of Magnetic Part ...

Страница 10: ... frame Base of Main Body is fastened to the right position of door frame or window frame via 2 pieces of screw Similarly fix Base of Magnetic Part on the right position of door or window via 2 pieces of screw 6 Door Frame Door Base of Main Body Base of Magnetic Part ...

Страница 11: ... Paste PE form tape on the base of product and then stick the product in the selected place Notes Before installation please keep the selected place tidy and clean Step 3 Put 1 CR2 battery into battery compartment of main body 7 Battery Notes Join the network before fastening this product ...

Страница 12: ...Step 4 Aim Main Body Main Body of Magnetic Part at the respective card slot of main body to fix them Step 5 Installation Finish 8 ...

Страница 13: ...igBee Network 1 Before setting please make sure the gateway additional purchase works normally Ensure that power is supplied to this product and it is within the effective communication range of the gateway 9 ...

Страница 14: ...an 1s While searching networking System Indicator is flashing After joining ZigBee network successfully System Indicator is on 2 seconds and then goes out CR2 1 2 10 Quickly click 4 times and each click is less than 1s After joining the network successfully System Indicator is on 2 seconds and then goes out ...

Страница 15: ...T Key 10 seconds System Indicator flashes 4 times then goes out to restore to factory setting The default setting for factory setting does not join ZigBee network CR2 1 2 Long press 10s Flashes 4 times and then goes out ...

Страница 16: ...ontrol the monitor information of this product by smart mobile terminal Once door frame or window frame is illegally open this product will send alarm signal to smart mobile terminal so that user can know all to take corresponding measures ...

Страница 17: ...Wipe the dust on the product by soft cloth Clean by the corrosive cleansing liquid and other chemical solvent is forbidden This product should be installed in dry and clean place to prevent inner component from dampness or other debris Please do not disassemble or refit this product and its accessories If this product breaks down non professional staff shall not handle it Send it to local service ...

Страница 18: ... installation Please confirm main body of door contact matches that of magnetic parts and size difference is within tolerance How to deal with it when this product is not online displayed on the smart APP A1 Please check if it s accessible to ZigBee network gateway within A2 Please check if sensor is installed in the effective communication range of gateway Besides switch on smart APP to check pow...

Страница 19: ...Purchasing Information Product Name Material Color Item No Model Smart Contact Sensor WL ZSPDBPW MT 01 PC White WLPN1448200 15 ...

Страница 20: ...package box of this product Option B Please visit our official website http www wulian cc service shtml for downloading Warm prompt For the first use please download smart home APP and read user manual carefully Please pay attention to Wulian information to download the latest APP in time ...

Страница 21: ...l regulations hand in the non working electrical equipments to an appropriate waste disposal centre Disposal and Recycling Information Statement Hereby Nanjing IOT Sensor Technology Co Ltd declares that this device is in compliance with theessential requirements and other relevant provisions of Directive 1999 5 EC 17 0700 ...

Страница 22: ...Building 11 No 15 Fengji Road Yuhuatai District Nanjing P C 210039 Email overseas wuliangroup com Service Hotline 400 889 2891 www wulian cc ...

Отзывы: