Maintenance, cleaning, disposal

16

ba77048e01

02/2014

The measuring instrument is sent out in a protective 
transport packing. 
We recommend: Keep the packing material in case you 
have to send the measuring instrument back for service. 
The original packing prevents the measuring instrument 
from being damaged during transport.

Dispose of the measuring instrument as electronic 
waste at an appropriate collection point. It is illegal to 
dispose of it in household refuse.
Within the European Union, the batteries are removed 
at a specialized treatment center at the instrument's end 
of life. The instruments are taken to one of those 
specialized treatment centers via the recycling system 
set up for this purpose.

Disposal

Packing

Measuring instrument

Содержание photolab S12

Страница 1: ...OPERATING MANUAL ba77048e01 02 2014 photoLab S12 PHOTOMETER ...

Страница 2: ...2 ba77048e01 02 2014 photoLab S12 Scope of delivery Photometer Power pack Product documentation Copyright 2016 Xylem Analytics Germany GmbH Printed in Germany ...

Страница 3: ...tions 6 Qualification of the personnel 6 Technical state of the meter 7 Commissioning 8 Preparing the photometer 8 Switching on the photometer 8 Measuring the concentration 9 Measuring using cell tests 9 Measuring using reagent tests 10 Zero adjustment 11 Meter Setup 13 Selecting the language 13 Setting the date time 14 Maintenance cleaning disposal 15 Maintenance Changing the lamp 15 Cleaning Act...

Страница 4: ...nt key e Concentration measurement key f Notch for cell alignment g Round cell shaft h Storage space for analysis regulations short form i Cover with integrated on off switch j Rectangular cell shaft k Keypad numeric keypad cursor function erase comma Identifying the connectors a Power pack b Connection for power pack c RS 232 interface ...

Страница 5: ...ected z Call up the meter setup submenu by pressing 1 The required menu item is Select 3or 28 Call up 1 Selection lists Changes to the settings are accepted after confirmation by pressing 1 Current settings are marked by S Change to other configuration levels by Selecting the menu item return Pressing 1 Scrolling with 3or 28 Character input via the numeric keypad or by using 3 the character to be ...

Страница 6: ...air work must only be performed by personnel authorized by the manufacturer The only exceptions to this are the activities described in chapter MAINTENANCE CLEANING DISPOSAL Non compliance results in the loss of warranty claims Follow the points listed below when operating the photometer Follow local safety and accident prevention regulations Observe the enclosed instructions concerning reagents a...

Страница 7: ... the meter If safe operation is no longer possible the equipment must be taken out of service and secured against inadvertent operation Safe operation is no longer possible if the equipment has been damaged in transport the equipment has been stored under adverse conditions for a lengthy period of time the equipment is visibly damaged the equipment no longer operates as prescribed If you are in an...

Страница 8: ... DESCRIPTION document on CD ROM Preparing the photometer Place the photometer on a hard flat surface and protect it against intensive light and heat Line operation Plug the original power pack into the socket on the photometer Plug the power pack into the line socket Switch on the photometer open the cover Battery operation Charge the battery for approx 5 hours before the initial commissioning To ...

Страница 9: ...shaft until it clicks into place Align the line mark to the notch of the photometer The photometer reads the barcode of the round cell and automatically selects the relevant method The measured value appears on the display If the select method menu is displayed align the line mark of the round cell or AutoSelector to the notch of the photometer 4 Measuring using cell tests Afterapprox 2 s ...

Страница 10: ...he rectangular cell vertically to the right of the slot The measurement starts automatically Observe the position mark at the cell shaft If the select method menu is displayed insert the corresponding AutoSelector into the round cell shaft If the cell type query appears select the relevant rectangular cell 10 mm 20 mm 50 mm with 3or 28 confirm with 1 The measured value appears on the display Measu...

Страница 11: ...k article 14693 If the round cell is visibly contaminated or at least every 24 months clean and refill it minimum filling level 20 mm Then check the cell for scratches When performing the zero adjustment with a rectangular cell observe the following points With rectangular cells the adjustment must be made using the same cell type manufacturer as for the measurement This is important because glass...

Страница 12: ...etup menu call up the meter setup submenu The following display appears Call up the zero adjustment submenu with 3or 28 Insert a cell with distilled water The message measuring appears on the display Successful zero adjustment for the 10 mm rectangular cell The zero adjustment must be performed separately for each cell type Afterapprox 2 s ...

Страница 13: ...is selected as the language the Cyrillic alphabet is used for the user guidance Method designation and ID numbers are always displayed in Latin script For output to the RS 232 C interface Cyrillic characters are converted to Latin characters according to GOST Call up the select language menu item Select a language e g Deutsch Confirm with 1 Press the 1key again Return to the meter setup submenu Th...

Страница 14: ...Meter Setup 14 ba77048e01 02 2014 Call up the set date time menu item Input the date via the numeric keypad Confirm with 1 Input the time via the numeric keypad Confirm with 1 Setting the date time ...

Страница 15: ...wer line Press and hold 3 Switch on the meter open the cover and after the following display appears release 3 Press 1 Perform zero adjustment according to chapter ZERO ADJUSTMENT Cleaning Actions to take if a cell is broken Do not rotate the photometer to pour out the liquid The photometer has a draining mechanism under the cell shaft that when operated correctly prevents any liquid coming into c...

Страница 16: ...ring instrument from being damaged during transport Dispose of the measuring instrument as electronic waste at an appropriate collection point It is illegal to dispose of it in household refuse Within the European Union the batteries are removed at a specialized treatment center at the instrument s end of life The instruments are taken to one of those specialized treatment centers via the recyclin...

Страница 17: ...sage still appears return the photometer to the service department lamp defective Replace the lamp see chapter MAINTENANCE CLEANING DISPOSAL no zero adjustment No zero adjustment is stored in the meter for the cell Perform zero adjustment see chapter ZERO ADJUSTMENT cell error The rectangular cell is inserted incorrectly or two cells are inserted Insert the cell correctly cell invalid A cell type ...

Страница 18: ...What to do if 18 ba77048e01 02 2014 ...

Страница 19: ......

Страница 20: ...s buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise backed by a legacy of innovation Xylem Analytics Germany GmbH Dr Karl Slevogt Str 1 82362 Weilheim Germany Xylem Analytics Germany Sales GmbH Co KG WTW Dr Karl Slevogt Str 1 82362 Weilheim ...

Отзывы: