6.6 Outgoing office number and internal host extension
The outgoing office number of any exterior line is default 9, the value can be set
as any value between 0-9.
The system supports the mixed existence of multiple outgoing office numbers,
and different number can be set for each outside line.
However, when choosing an outgoing office number, you must be careful not to
use the same value as internal host extension code or prefix of any extension number.
Because outgoing office numbers have the highest priority, if they are the same as the
others, the other functions will not work properly. When the extension dials this
number, it will directly select the exterior line.
Example:
Change all outgoing office numbers to 0, and set dial 9 to call extension
8007.
Operation:
Step 1: Change all outgoing office numbers of exterior to 0.
The programming host extension off-hook, then dial *#99 6666# into
programming mode, continue to dial 224 0#, and proceed to the next step after hearing
the prompt tone.
Instruction: 224 AB K#
Change the outgoing office number of exterior.
Directive: 151 K#
Change the value of internal host extension code, default is 0.
Instruction: 153 Q#
Change the value of internal host extension number, default is extension 1.
Description:
AB is 01-32, means exterior line 1-32. When AB is omitted, the
instruction indicates the batch setting of all exterior ports.
k is 0-9, means the outgoing office number of exterior line.
Q is the extension number with 1-5 digits.
WEB:WWW.WS824.ORG TEL:020-85261379 18144823824