background image

2

1.When using, do not permit any person stand at the oil output in order to avoid personal injury and

equipment damage. Please put the pump far away from the fire. 

2.Make sure that the hose and quick coupler be connected before building up the pressure in order

to avoid hydraulic fluid spurting out to cause personal injury.

3.The  maximum  operating  pressure  of  this  pump  is  700Bar,WREN  has  set  up  the

pressure to 700Bar before selling this pump. Please do not adjust to a pressure higher than 

the maximum pressure which WREN has not set.

4.If this pump is used for operating other equipments, make sure the maximum operating pressure

of the equipments will be less than 700Bar. Please adjust the pressure to which the equipment 

need, or else the equipment would be damaged.

5.Make sure the power of the pump is shut off before repairing it.

6.Please shut off the switch before starting power; if the switch is on, the pressure may increase.

7.Make sure the equipment be connected with ground to avoid electric shock.

8.Please do not change any part of the pump; if it must be changed, please inform WREN or Wren's

agent for help. Without allowance of  WREN or its agent, any refit of it will be out of our warranty 

range.

9.Please do not fill the pump reservoir with too much oil, otherwise, the pressure of the reservoir will

increase  and  the  oil  will  spill  over,  so  the  reservoir  will  be  broken  and  the  environment  will  be 

polluted.

10.Automatic operation button is pressed, the automatic cycle start button switch bounce, automatic

program stop. Under a state of emergency, you must first cut off the power supply of a motor.

11.Make  sure  the  quick  coupler  is  tightened;  if  the  quick  coupler  is  not  tightened  enough,  the

equipment will not work normally; if it is a synchronic system, the problem may cause one or several 

pieces of equipment out of order and the quick coupler may be broken and it may cause personal 

injury or equipment damage.

12.Please stand away from the position where the hydraulic oil may be spurt out; hydraulic oil may

penetrate your hand and hurt you.

13.If the hydraulic oil splashed in your eyes, please immediately wash your eyes about 15 minutes

with clean water, then you must go to hospital for help right now.

14.Electrical box with flashing lights. If the bright lights, the circuit fault. Usually the indicator does

not work. If there is light to timely repair

15.The wrench and power pump are connected by a 700 Bar operating pressure, twin-line hose

assembly. Each end of the hose will have one male and one female connector to assure proper 

interconnection between pump and wrench.

16.Please do not touch the pressurized hose; if the hydraulic oil splashed out, it will cause serious

injury.

1.Only WREN hydraudic special oil available.

2.Do not use pressure regulate valve as relief valve.

3.The used hydraulic oil should be put away according to the antipollution ordinance.

PRECAUTION

Motor Switch

(Control the Motor)

Button for manual operation

(Control by hand)

Button for automatic operation

(Press down the button 

till operation finished)

Содержание KLW4120

Страница 1: ...ols WREN Hydraulic Safety Guide The hydraulic torque wrench pump s safe usage requires correct operation and regular inspect And the user is requested to follow always and carefully precaution to avoi...

Страница 2: ...Automatic operation button is pressed the automatic cycle start button switch bounce automatic program stop Under a state of emergency you must first cut off the power supply of a motor 11 Make sure t...

Страница 3: ...st the pressure valve arbitrarily to avoid personal injury or equipment damage due to high pressure 8 Please confirm that the voltage for this pump is the same as the voltage of using on the spot 9 Yo...

Страница 4: ...on of the pump 1 Making sure the pump must be turn down 2 Please inspect whether there are leaky or abnormal condition or not If there is abnormal situation please inspect to find the reason and repai...

Страница 5: ...e air discharged high pressure hose 6 press the manual button time to observe the pressure gauge pointer is upward otherwise the pressure pump station work is not normal please check the troubleshooti...

Страница 6: ...theair Suck in air to the system Thethrottleandhandsingle direction valvehaven t beentightened Locking valve Thethrottleandhandsingle direction valvehaven t beenadjustedtothe correct position Adjust t...

Страница 7: ...1 2 3 4 5 6 7 Item 8 9 10 11 12 13 14 Description Description Oil Reservoir Gauge Frame For Protecting Regulating Valve Valve Assembly Oil Lever Measure Oil Releasing Port Electrical Control System Mo...

Страница 8: ...e Low Valve Body O Ring Retaining Ring O Ring O Ring Relief Valve Middle Valve Body O Ring Retaining Ring O Ring O Ring Filter Fixer Screw Safety Valve Check Valve Valve Body Retaining Ring O Ring O R...

Страница 9: ...alve Body O Ring O Ring Quantity 1 1 1 2 1 2 2 1 1 1 5 5 1 1 1 1 1 O Ring Solenoid Valve O Ring 1 2 1 Item 9 10 10 1 10 2 10 3 11 12 12 1 12 2 12 3 12 4 13 13 1 13 2 13 3 14 15 16 17 18 Description Ga...

Страница 10: ...HYDRAULIC PRINCIPLE 70 10...

Страница 11: ...tz Fischer Address of authorized person PETER ROSEGGERSTR 12 GERMANY 85293 REICHERTSHAUSEN MAILBOX hstfischer t online de DESCRIPTION OF MACHINERY PRODUCT NAME HYDRAULIC PUMP MODEL TYPE KLW4000 Series...

Страница 12: ......

Страница 13: ...KLW4120 WREN WREN 1 KLW4120...

Страница 14: ...2 1 2 3 70Mpa 70Mpa 4 70Mpa 5 6 7 8 WREN WREN WREN 9 10 11 700bar 12 13 14 15 15 1 WREN 2 3...

Страница 15: ...1 2 3 4 5 6 7 2 3 100Mpa 4 5 6 1 1KLW4120 A 70 700Bar 1 2 32 36 6 1 3 10 60 1 4 WREN WREN 100Mpa 1 5 WREN 1 6 1 7 KLW4120 1...

Страница 16: ...mmended in operating instructions must be used in this pump Do not use pump in any type of explosive flammable or gas environment Escaping hydrauic fluid under pressure can have sufficient force to pe...

Страница 17: ...1 1 1 1 2 1 3 1 4 2 2 1 2 2 2 3 2 4 3 3 1 3 2 3 3 4 4 1 4 2 4 3 4 4 5 5 1 5 2 5 3 15...

Страница 18: ...1 KLW4120 KLW41 20 70db 2 KLW4120 2 1 2 2 2 3 2 1 32 46 2 3 4 2 3 5 6 T 7...

Страница 19: ...O...

Страница 20: ...1 2 3 4 5 6 1 2 2 7 8 9...

Страница 21: ...2 9 3 2 9 4 2 9 5 2 10 2 10 1 2 10 2 2 10 3 2 10 4 2 11 2 12 2 13 2 14 2 15 2 16 2 17 2 18 2 19 2 20 2 21 2 22 2 23 2 24 2 25 2 26 2 27 2 28 1 O O O O 2 O O 1 2 3 1 1 1 4 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1...

Страница 22: ...1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 2 1 2 1 9 4 3 9 4 4 9 5 9 5 1 9 5 2 9 5 3 9 6 9 7 9 7 1 9 7 2 9 7 3 9 8 9 8 1 9 8 2 9 8...

Страница 23: ...M1 M2 SB 1 SB 2 SB 3 SB1 SB1 SB2 SB2 SB3 SB3 O YC SP 1 SP 2 SP1 SP2 SP2 SP1...

Страница 24: ...2 R 120mm 3 70Mpa 4 5 6 7 8 WREN JH 100Mpa 100Mpa 1 WREN WREN 2 WREN WREN 3 1 WREN Jh...

Страница 25: ...Single Phase 7 2A 2800r min 1 1 7 1 6 0 8 NPT1 4 NPT1 4 70 KLW4120B 7 E 200 240V 60HZ 4Pole Single Phase 6 2A 1720r min 0 9 5 5 1 4 0 7 NPT1 4 NPT1 4 70 KLW4120C 7 E 100 120V 50HZ 2Pole Single Phase 1...

Страница 26: ...47 0 405 km 0 39 2 59 cm 0 061 16 4 L 61 0 016 1 ML 0 034 29 6 L 1 06 0 946 1 L 0 26 3 79 1 m 1 3 0 76 g 0 035 28 36 kg 2 2 0 454 t 1 1 0 907 N 0 225 4 45 KN 225 0 00445 N M 8 9 0 113 N M 0 74 1 36 kp...

Страница 27: ...www wrenchina com...

Отзывы: