background image

5.Electronic control box: Built-in micro electronic control system, control the entire pump.

oil used in oil );  cover with ventilation holes,  filling the oil cover,  a filtering net is arranged

to ensure that no impurities into the tank; tightening oil cover ensure system of air discharg

7.Liquid level gauge: Observation of hydraulic oil to ensure that the number, provide the best use of
oil;  hydraulic oil below the oil standard1 /3 position,  must add WREN pumping station hydraulic oil,
or

 

may

 

damage

 

the

 

pump

 

station.

8.Oil unloading hole: Plug G1/ 4",  realize hydraulic oil discharge tank ( replacement of hydraulic oil
in use);
9.Fast joint :  The realization of hydraulic oil output \ return oil function,  fast connecting pipe built-in
type check valve;

10

.

Six

 

angle

 

screws

Sealing

 

connecting

 

tank.

1

.

H

LP3-

20

 

E

lectric

 

Tensioner P

ump

 

is

 

a

 

double

 

stage

 

pump

 

with

2000bar

 

maximum

 

operating

 

pressure

1.WARNING!!!

2.

When

 

operating, do

 

not

 

permit

 

anyone

 

stand

 

at

 

the

 

oil

 

output

,

The

 

oil

 

output

 

must

 

connect

 

other

 

components when adjusting the pressure.

3.

When using, do not overpass the max operating pressure.

4.

If

 

need

 

to

 

check

 

motor

 

tank

please

 

shut

 

off

 

the

 

pump

.

5.

When working, the oil back to oil reservoir may add the pressure. If open the cover plate,  unnec 

-essary injury and damage will happen.

5

.

Proihbit

 

to

 

operate

 

without

 

oil.

6

.

Keep

 

the

 

pump

 

clean

,

clean

 

especially

 

the

 

oil

 

inlet

quick

 

couplers

.

the hydraulic

 

oil.

3.

Motor voltage:220V

4.

Temperature: - 10~

6

 

5.

Oil 

tank

:

5.5

L

6.

ISO

 

VG

 

46

or 32#

anti-wearing 

hydraulic

 

oil

.

 

Warning

 

Plate

Warning

 

plate

 

is

 

shown

 

in

 

table

 

1

warning

 

table

Meaning

Affixed

 

Position

!

WARNING

To

 

help

 

avoid

 

personal

 

injury

,

read

 

the

 

opera

-

instructions

 

before

 

using

 

this

 

pump

.

ting 

Disconnect

 

the

 

power

 

supply

 

before

 

any

maintenance

 

is

 

performed

 

on

 

this

 

pump

.

All

electrical

 

work

 

must

 

be

 

done

 

by

 

a

 

qualified

electrical

.

Operators

 

of

 

this

 

hydraulic

 

power

 

supply

 

unit

or

 

operations

 

of

 

equipment

 

powered

 

by

 

this

unit

 

must

 

be

 

knowledgeable

 

of

 

hydraulic

equipment

 

hazards

 

if

 

any

 

hydraulic

equipment

 

is

 

used

 

incorrectly

.

Hydraulic

 

fluid

 

recommended

 

in

 

operating

instructions

 

must

 

be

 

used

 

in

 

this

 

pump

.

Do

 

not

 

use

 

pump

 

in

 

any

 

type

 

of

 

explosive

,

flammable

,

or

 

gas

 

environment

.

Escaping

 

hydrauic

 

fluid

 

under

 

pressure

 

can

have

 

sufficient

 

force

 

to

 

penetrate

 

the

 

skin

and

 

cause

 

serious

 

personal

 

injury

.

If

 

you

 

are

injured

 

by

 

escaping

 

hydraulic

 

fluid

,

seek

medical

 

attention

 

immediately

.

See

 

operating

instructions

 

for

 

further

 

precautions

 

to

 

help

prevent

 

the

 

possibility

 

of

 

hazards

 

occurring

due

 

to

 

escaping

 

hydraulic

 

fluid

.

The

 

Equipment

Enclosure

The

 

Equipment

Enclosure

Warning

 

Notices

For

 

Saf

e

 

Operation

,

Please

 

Read

CHARACTERISTIC

6.Ventilation hole : The realization of hydraulic oil discharge tank (replacement of hydraulic

-ed smoothly.

7.Suggestion:  in the  condition of not  using the pump always, please remembe r to replace

4

Содержание HLP3-20 Series

Страница 1: ...avoid direct loss in economic or property warning to avoid personal injury Please follow herein before When using if something abnormal happens please shut off the power immediately and then consult WREN or WREN s agent Safety Guide Electrical Tensioner Pump s safe usage requires correct operation and regular inspect the user is always requested to follow always and carefully regular inspect OPERA...

Страница 2: ...ing power if the switch is on the pressure may increase 8 Make sure the equipment be connected with ground to avoid electric shock 9 Please do not change any part of the pump if it must be changed please inform WREN or Wren s agent for help Without allowance of WREN or its agent any refit of it will be out of our warranty range 10 Please do not fill the pump reservoir with too much oil otherwise t...

Страница 3: ...c device has the advantages of small volume light weight simple structure convenient operation high work pressure Pump for high low pressure oil pump and oil supply it can obtain the larger oil output High pressure low pressure pump by unloading overflow valve automatic no load return oil can reduce the power consumption output pressure is 90 2000bar arbitrary regulating 2 Hydraulic oil 46 or 32 a...

Страница 4: ...Item Despription 1 Protective Frame 7 Electrical Control Box 2 I Pressure Gauge 8 Cooler 3 I Regulating Valve 9 Tank Plate 4 I Valve Block 10 Check Valve 5 I Oil Tank 11 Oil Filling Port 6 I Oil Releasing Port 12 Oil Gauge ...

Страница 5: ...l 6 Keep the pump clean clean especially the oil inlet quick couplers the hydraulic oil 3 Motor voltage 220V 4 Temperature 10 6 0 5 Oil tank 5 5L 6 ISO VG 46 or 32 anti wearing hydraulic oil Warning Plate Warning plate is shown in table 1 warning table Meaning Affixed Position WARNING To help avoid personal injury read the opera instructions before using this pump ting Disconnect the power supply ...

Страница 6: ...rmation 2 1 Handle with care 2 2 The shipment should be vertical upward as shown in the figure 9 1 2 3 Product handling generally using portable car handling and lifting and moving as shown in the figure 9 2 FIG 9 1 FIG 9 2 NOISE VIBRATIONAND TRANSPORT INFORMTION NOISE VIBRATIONANDTRANSPORT INFORMATION 6 ...

Страница 7: ...n 3 OPERATION 3 1 Press on the wire control switch self locking button the pump will output the pressure hydraulic bolt tensioner will start to work when the pressure is close to the set value releas e the self locking button Press the self resettable button on the control switch to make the pressure reaches the desired pressure 3 2 When the working pressure is same as the set required pressure pr...

Страница 8: ... t move please knock it with a hammer to eliminate the mist hydraulic oil Leakage in the quick coupler The o ring and escape have worn out Replace the quick coupler The pressure can t reach to the set pressure The relief valve is adjusted too low Check with the gauge and adjust the relief valve to the system set pressure Oil is mixed with water Change oil Not enough oil in the reservoir Fill in oi...

Страница 9: ...ssure Pump head low pressure Screw 2 Checking valve Regulating valve Relief valve low pressure Fitting Fitting O ring Bearing Sleeve Pump head high pressure Screw 3 Fliter press Retaining ring piston 1 High pressure piston Piston 2 Deep groove ball bearing 2 Retaining ring Eccentric sleeve Copper sleeve Bearing outer ring Eccentric block Multi tooth gasket Nut Screw 4 Screw 5 Filter cover ...

Страница 10: ...alve Block Item Description Quantity Item Description Quantity Gauge Gauge adaptor Regulating valve Needle valve Connector Steel ball 5 Ejector pin Spring Steel ball 6 35 Screw 1 Screw 2 Plug O ring Flat gasket Spring gasket Screw ...

Страница 11: ...ents control components Self locking Self retract Self locking Self retract Remark means connect and work means break and stop means no connection does not work Symbol Description working capacitence start capacitence breaker relay remote control button 1 remote control button 2 motor fan circuit broad ...

Страница 12: ...nents Self locking Self locking Self retract control components Motor Remark means connect and work means break and stop means no connection does not work Symbol Description Breaker transfomer high flow relay remote control button 2 motor fan remote control button 1 ...

Страница 13: ... to remove attached equipment Stress can damage the hose causing personal injury 6 Do not subject the hose to potential hazard such as fire sharp surfaces extreme heat or cold or heavy impact Do not kink twist or bend the hose so tightly that oil flowing in the hose is blocked or reduced Periodically inspect the hose for wearing because any of these conditions can damage the hose 7 Should any hydr...

Страница 14: ...tor V Hz Power Kw Flow Rate L min Oil Port Max Pressure HLP3 20A 5 5 BV 220V 50HZ 1 1 5 5 0 45 G1 4 2000 HLP3 20B 5 5 BV 220V 60HZ 0 9 4 2 0 45 G1 4 2000 HLP3 20C 5 5 BV 1 1 G1 4 2000 HLP3 20D 5 5 BV 115V 60HZ 0 9 4 2 0 45 G1 4 2000 115V 50HZ 4 2 0 45 Bar ...

Страница 15: ...renchina com RECYCLED All Wren products are guaranteed against defects in workmanship and materials for as long as you own them Under this guarantee free repair or replacement will be made to your satisfation ...

Отзывы: