Page 20
MODELS
KW(N311, P312)
N311 P312
KW(N181, P182)
N181 P182
INPUT RATING
(BTU/HR,Variable)
6,400/18/000/30,000
NATURAL
LP GASES
NATURAL
LP GASES
6,400/18,000/30,000 6,400/12,000/18,000 6,400/12,000/18,000
TYPE OF GAS
REGULATOR
PRESSURE SETTING
INLET GAS SUPPLY
PRESSURE
MAXIMUM
MINIMUM
6.0
″
W.C.
10.5
″
W.C.
7.0
″
W.C.
10.0
″
W.C.
14.0
″
W.C.
11.0
″
W.C.
6.0
″
W.C.
10.5
″
W.C.
7.0
″
W.C.
23.8
″×
25.7
″×
8
″
30LBS
22LBS
23.8
″×
18.3
″×
8
″
10.0
″
W.C.
14.0
″
W.C.
11.0
″
W.C.
SIZE OF HEATER
(H
×
W
×
D)
WEIGHT
OPTIONAL ACCESSORIES
: Purchase these heater accessories from your local
distributors/dealers. If they can not furnish these items, call World Marketing of America, Inc.
@1-814-643-2299 for more detailed information.
FLOOR MOUNTING BASE : N
O
. 20-5231 may be used for MODEL(KWN 311, KWP 312).
No. 20-5221 may be used for MODEL(KWN 181, KWP 182).
"DO NOT USE THIS HEATER AT AN ELEVATION ABOVE 4,500 FEET"
NOTE
: For altitudes above 2,000 feet, reduce the input rating(BTU/HR)4% for
each 1,000 feet above sea level.
SPECIFICATIONS: