in high traffic areas
in windy or drafty areas

IMPORTANT : Vent-free heaters  add  moisture to  the  air. Although  this  is

beneficial, installing heater  in rooms without enough  ventilation
air may cause  mildew formation from too  much moisture  content.
See  National  Fuel Code  for  Fresh Air  for Combustion  and
Ventilation.
This appliance may be installed in an aftermarket* manufacture
(Mobile) home, where not prohibited by state or local codes.

*Aftermarket : Completion of sale, not for purpose 

of resale, from the manufacturer.

This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases.

CAUTION :

If you install the heater in a home garage:

Heater must be at least 18 inches above floor.
Locate heater where moving vehicle will not hit it.

Preparing For Installation

Select a location for the heater that will provide maximum exposure of the radiant
surface to the room, but will not be subjected to accidental contact.
Adequate clearance must be available around the air opening.  See figures 1 & 2 for
clearances that must be maintained to the side walls, floor and horizontal surface
surrounding the heater.

Attaching Mounting Brackets To Wall

Note:Wall anchors, mounting screws, and spacers are in hardware package.
The hardware package is provided with heater

2"

Minimum to top surface
of carpeting. Tile or other
combustible material

Right
side

36"
Minimum

13"

CEILING

FLOOR

Left
side

Minimum
from
sides of 
heater

Figure 1

Figure 2

Содержание Kozy-World KWN181

Страница 1: ...any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a nei...

Страница 2: ...al Safety Instructions Product Identification Local Codes National Fuel Code Unpacking the Heater Package Product Features Fresh Air for Combustion and Ventilation Installation Gas Requirements Leak C...

Страница 3: ...ocated so that you know where to shut off the gas to the heater If you smell gas your installer has not done a proper job of checking leaks If the connections are not perfectly seated or tightened you...

Страница 4: ...room heater and to replace any part of the control system and any gas control which has been under water Keep appliance area clear and free from combustible materials gasoline and other flammable vapo...

Страница 5: ...g instructions to insure proper fresh air for this and other fuel burning appliances in your home ADEQUATE COMBUSTION VENTILATION AIR All spaces in homes fall into one of the three following ventilati...

Страница 6: ...LP Propane and make sure the marking on the appliance rating plate agrees with that of the supply gas The rating plate is located on the side of the heater which indicates the type of gas that heater...

Страница 7: ...other gases CAUTION If you install the heater in a home garage Heater must be at least 18 inches above floor Locate heater where moving vehicle will not hit it Preparing For Installation Select a loc...

Страница 8: ...o wall as shown in Fig 4 4 Insert mounting screws through each bracket and into wall anchors 5 Tighten screws until mounting bracket is firmly fastened to wall Installing Bottom Mounting Screws 1 Loca...

Страница 9: ...0 Inches Sides 13 Inches Top 36 Inches Floor 2 Inches NOTICE Maintain the minimum clearances shown in Figure 1 but you can provide greater clearances from floor ceiling and adjoining wall 2 After moun...

Страница 10: ...line pressure is higher heater gas pressure regulator damage could occur CAUTION Use only new black iron or steel pipe and internally tinned copper tubing may be used in certain areas Check your local...

Страница 11: ...LP units check with a full cylinder CAUTION NEVER LEAK TEST WITH AN OPEN FLAME PRESSURE TESTING GAS SUPPLY PIPING SYSTEM The appliance and its individual shutoff valve must be disconnected from the g...

Страница 12: ...urner and safety valve the burner must be lit See operating Instructions Check the rest of the connections for leaks 7 Turn off the heater See Instructions NOTE Never use an open flame to check for a...

Страница 13: ...follow the safety information on the front page If you don t smell gas go to the next step 5 Push in gas control knob slightly and turn counterclockwise to PILOT IGN and depress for five 5 seconds NOT...

Страница 14: ...levels of carbon monoxide may result CAUTION Do not try to adjust heating levels by using the manual shutoff valve OFF P I L O T I G N LO W MED HIGH OFF P I L O T I G N LO W MED HIGH OFF P I L O T I G...

Страница 15: ...trike match hold match to pilot until pilot lights 5 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob 6 Replace lower front panel INSPECTING MAIN...

Страница 16: ...off position Make sure the heater is cool BURNER AND ODS PILOT CLEANING Clean the exterior with soft bristle brush vacuum cleaner pressurized air Never use a wooden toothpick as it may break off and c...

Страница 17: ...couple which allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermoco...

Страница 18: ...between locked positions 1 Residues from manufacturing processes 1 Air passageways blocked 2 Air in gas line 1 Metal expanding and contracting respectively 1 Gas leak see front page Warnings 2 Gas con...

Страница 19: ...artially clogged 1 Heater burning vapors from paint hair spray glues etc See IMPORTANT statement above 2 Gas leak See Warning statement at top of page 1 Not enough combustion ventilation air 1 Check g...

Страница 20: ...18 3 8 10 0 W C 14 0 W C 11 0 W C SIZE OF HEATER H W D WEIGHT OPTIONAL ACCESSORIES Purchase these heater accessories from your local distributors dealers If they can not furnish these items call World...

Страница 21: ...Page 21 PARTS LIST...

Страница 22: ...Valve Link Link Fix Pin Connector D NAT Connector D1 NAT ODS Mounting Screw Wall Mounting Screw Screw PART NO FOR KW N311 P312 KW N181 P182 REF 2A0052 20 0142 1A0038 REF 2A0047 20 1717 3A0054 REF 4A0...

Страница 23: ...A PARTICULAR PURPOSE THE REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES IN NO EVENT WILL WORLD MARKETING OF AMERICA BE LIABLE FOR INCIDENTAL OR CONSEQUENTIA...

Страница 24: ...ck is not as bright as another your heater is probably due for a good cleaning Replacement of the thermocouple or pilot assembly is generally not needed Review Heater Maintenance on page 15 of the own...

Отзывы: