Error code
Name
Description
Possible solution (initialization = reset)
E01
Unknown height
error in reading current altitude
E02
Overload up
Overload in outward motion
E03
Overload down
overbelasting in neerwaartse beweging
E08
Unexpected reset
E09
LIN-bus error
E10
Power-error
E11
Number of channels changed
E12
Position difference
E13
Short circuit
E14
Control
E15
Power cut
E16
Invalid key
E17
No safety
E18
Missing initialization plug
E23
E24
E25
E26
E27
E28
E29
E30
E31
E32
E33
E34
E35
E36
E37
E38
E39
E40
*Not applicable if the lower position is limited.
Step 1: Put the desk at the lowest position.
Step 2: After the desk is in its lowest position,
release the control and then hold it down again
until the desk makes a small movement down
and up.
Initialization (Reset):
Error codes
Initialization
Better weight distribution between columns/remove excess weight/initialization
Better weight distribution between columns/remove excess weight/initialization
Initialization
An error occur on LIN bus
Initialization
Power failure occurred or regulator power set below 10%
Check mains power
Number of channels connected to the system has changed since the last initialization
Initialization
Difference between minimum and maximum position of reference has been exceeded Initialization
Short circuit is detected during use
Remove power cord/ check cables/ initialization
Position check failed, all channels have lost position
Initialization
System has reached the power limitation
Obstacle removal / in misalignment initialization
Invalid key combination
Press a maximum of 1 key at a time
Safety function does not allow movement but a key has been pressed
Obstacle removal / in misalignment initialization
A special service tool /plug is re
q
uired to change the number of channels in the control box
contact supplier
Channel 1 is missing
An actuator on channel is missing :
check motor cable/start at port 1 /initialization/
Channel 2 is missing
check motor cable/start at port 1 /initialization/
Channel 3 is missing
check motor cable/start at port 1 /initialization/
Channel 4 is missing
check motor cable/start at port 1 /initialization/
Channel 5 is missing
check motor cable/start at port 1 /initialization/
Channel 6 is missing
check motor cable/start at port 1 /initialization/
Channel 1 type
The type of actuator connected is different than during initialization
OR traffic detected Initialization by the system
Channel 2 type
The type of actuator connected is different than during initialization OR
traffic detected by the system OR not e
q
ual to actuator channel 1
initialization/check item numbers
Channel 3 type
initialization/check item numbers
Channel 4 type
initialization/check item numbers
Channel 5 type
initialization/check item numbers
Channel 6 type
initialization/check item numbers
Channel 1 pulse
Too much pulse errors
Initialization
Channel 2 pulse
Initialization
Channel 3 pulse
Initialization
Channel 4 pulse
Initialization
Channel 5 pulse
Initialization
Channel 6 pulse
Initialization
overload in downward motion
Initialization