Worktrainer Linak SmartDesk Скачать руководство пользователя страница 6

-

-

Error code

Name

Description

Possible solution (initialization = reset)

E01

Unknown height

error in reading current altitude

E02

Overload up

Overload in outward motion

E03

Overload down

overbelasting in neerwaartse beweging

E08

Unexpected reset

E09

LIN-bus error

E10

Power-error

E11

Number of channels changed

E12

Position difference

E13

Short circuit

E14

Control

E15

Power cut

E16

Invalid key

E17

No safety

E18

Missing initialization plug

E23

E24

E25

E26

E27

E28

E29

E30

E31

E32

E33

E34

E35

E36

E37

E38

E39

E40

*Not applicable if the lower position is limited.

Step 1: Put the desk at the lowest position.

Step 2: After the desk is in its lowest position,
release the control and then hold it down again
until the desk makes a small movement down
and up.
 

Initialization (Reset):

Error codes

Initialization

Better weight distribution between columns/remove excess weight/initialization

Better weight distribution between columns/remove excess weight/initialization

Initialization

An error occur on LIN bus

Initialization

Power failure occurred or regulator power set below 10%

Check mains power

Number of channels connected to the system has changed since the last initialization

Initialization

Difference between minimum and maximum position of reference has been exceeded Initialization

Short circuit is detected during use

Remove power cord/ check cables/ initialization

Position check failed, all channels have lost position

Initialization

System has reached the power limitation

Obstacle removal / in misalignment initialization

Invalid key combination

Press a maximum of 1 key at a time

Safety function does not allow movement but a key has been pressed

Obstacle removal / in misalignment initialization

A special service tool /plug is re

q

uired to change the number of channels in the control box

contact supplier

Channel 1 is missing

An actuator on channel is missing :

check motor cable/start at port 1 /initialization/

Channel 2 is missing

check motor cable/start at port 1 /initialization/

Channel 3 is missing

check motor cable/start at port 1 /initialization/

Channel 4 is missing

check motor cable/start at port 1 /initialization/

Channel 5 is missing

check motor cable/start at port 1 /initialization/

Channel 6 is missing

check motor cable/start at port 1 /initialization/

Channel 1 type

The type of actuator connected is different than during initialization
OR traffic detected Initialization by the system

Channel 2 type

The type of actuator connected is different than during initialization OR
traffic detected by the system OR not e

q

ual to actuator channel 1

initialization/check item numbers

Channel 3 type

initialization/check item numbers

Channel 4 type

initialization/check item numbers

Channel 5 type

initialization/check item numbers

Channel 6 type

initialization/check item numbers

Channel 1 pulse

Too much pulse errors

Initialization

Channel 2 pulse

Initialization

Channel 3 pulse

Initialization

Channel 4 pulse

Initialization

Channel 5 pulse

Initialization

Channel 6 pulse

Initialization

overload in downward motion

Initialization