IMPORTANT NOTE!

You must complete initialization (Step 13) at the end of 

assembly or your work center WILL NOT FUNCTION PROPERLY.

WARNING: 

Maximum loading of table assembly is 300 lb (136 kg). Maximum load includes 

the weight of the table top itself, any equipment placed upon it, and any equipment suspended or hanging under 
it. Loading should be evenly distributed over table surfaces. “Payload Capacity” is the Workrite Ergonomics 
recommended maximum loading which includes the Workrite sourced worksurface.

Sierra 3-Leg
V = 120 VAC, 60 Hz / 4.25 A maximum

FLAMMABILITY: All worksurfaces used must meet UL962 flammability requirements 

•  Flame Spread Rating maximum 200

•  Smoke Developed Index maximum 450
WORKSURFACE SIZE: This frameset is designed to accommodate worksurfaces made from Industrial Particle Board  

with the following dimensions:

Dimensions

 (inches):

40"–46"wL

 × 

76"– 90" wR

 × 

23"–29"d

76"–88"wL

 × 

40"– 46" wR

 × 

23"–29"d

IMPORTANT SAFETY INSTRUCTIONS:

When using an electrical furnishing, basic precautions should always be followed, including the following:
Read all instructions before using this Sierra Work center.

DANGER:

 

To reduce the risk of electric shock, always unplug this Sierra Work center from the 

electrical outlet before cleaning. 

WARNING:

 

To reduce the risk of burns, fire, electric shock, or injury to persons:

1.  Unplug from outlet before putting on or taking off parts.
2.  Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled persons.
3.  Use this furnishing only for its intended use as described in these instructions. Do not use attachments not 

recommended by the manufacturer.

4.  Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been 

dropped or damaged, or dropped into water. Return the furnishing to a service center for examination and 

repair.

5.  Keep the cord away from heated surfaces.
6.  Do not use outdoors.
7.  Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
8.  To disconnect, remove plug from outlet.
9.  Each surface intended to support an equipment payload capacity of 225 pounds.

FOR COMMERCIAL USE ONLY

SAVE THESE INSTRUCTIONS 

Содержание Sierra SEHX7890-4272OC Series

Страница 1: ...Qty 2 A Leg Qty 3 E Short Bracket Qty 3 OControl Box Qty 1 L Corner Foot Qty 1 MFoot Glides Qty 4 F Left End Bracket Qty 1 GRight End Bracket Qty 1 HCorner End Bracket Qty 1 K 12 Pan Head Laminate Top...

Страница 2: ...al furnishing basic precautions should always be followed including the following Read all instructions before using this Sierra Work center DANGER To reduce the risk of electric shock always unplug t...

Страница 3: ...et Assemble Rear Brackets B to Connector Bracket C using M6 12 mm Flat Head Cap Screws X Use this guide to determine the correct holes for mounting based on the width of your work center Tighten secur...

Страница 4: ...eads always insert and make the first few turns of the screw BY HAND with an Allen wrench J ensuring it is in straight C C C B B B B Use with 70 23 70 29 or 64 23 widths Use with 64 29 or 58 23 widths...

Страница 5: ...et is on the longer of the two sides Tighten securely Note The Right End Bracket G will be on your left when upside down Note Left configurations will assemble as a mirror image of these instructions...

Страница 6: ...lot holes at the six corner locations You may wish to mark your drill bit so you do not drill any more than deep and damage your worksurface top Do not drill all the way through worksurface 6 125 23 3...

Страница 7: ...river be sure it is on the lowest torque setting to avoid stripping the holes in the top 5 2 Drill all remaining pilot holes first then install all remaining 12 Pan Head Laminate Top Screws K Tighten...

Страница 8: ...ck to route cord 8 2 Thread the 1 meter Leg Cable R from the Center Leg through the cable channel on the bottom of the Control Box as shown Leave 8 of slack to route cable 8 3 Plug Power Cord T into p...

Страница 9: ...ere marked Do not drill all the way through tabletop 9 2 With Control Box O positioned over pilot holes attach with two 12 2 Flat Head Screws N 9 3 Attach Cable Spool P with the 12 Pan Head Screw K to...

Страница 10: ...ps Q to underside of worksurface using 8 Pan Head Screw I making sure to wrap the Cable Loop around the cable prior to attaching Attach cable loops in convenient locations between legs or switch and t...

Страница 11: ...the Right Leg A and port 1 on the Control Box O Connect the Center Leg Cable R to the port on the Center Leg A 11 2 Insert the Switch Cable into port A1 on the Control Box O 11 3 Connect 2 Meter Leg C...

Страница 12: ...instructions To clean the Sierra legs apply cleaner to a soft cloth Suggested cleaners Windex or Formula 409 Do not use solvents and do not saturate or spray cleaners directly to work center base You...