2.7.11 Reference Signal Input  

At the 

Ref. In

 connector (BNC, 50 

W

, female) an external reference signal can be connected. The frequency 

can be either 10 MHz or 5 MHz. See chapter 3.5.2.7 for configuration options and details about this input. 

2.7.12 IF Input Connector 

The  IF  input  signal  is  connected  to  the 

“I

F  In

  connector  at  the  rear  panel.  The  type  of  connector  is  BNC, 

50 Ohm or SMA (720 MHz IF), 50 Ohm, female. With dual channel devices, two IF inputs are available. 

2.7.13 Ground Terminal 

The ground terminal is a blade type connector with the width 6.3 mm. 
 

Important:  For  save operation,  this  ground  terminal  must  be  permanently  connected  to  a  grounding 
point! 

 

Содержание VHCU

Страница 1: ...Satellite Upconverter Type VSCU VHCU User Manual WORK Microwave GmbH Raiffeisenstrasse 12 83607 Holzkirchen Germany Tel 49 8024 6408 0 Fax 49 8024 6408 40 E Mail sales work microwave com...

Страница 2: ......

Страница 3: ...2 Signal Flow 11 2 3 3 Local Oscillators 12 2 3 4 Warm Up Period 12 2 4 Power Supply 12 2 5 Front Panel 13 2 6 Rear Panel 13 2 7 Connectors on the Rear Panel 15 2 7 1 Mains AC Input Connector Block 1...

Страница 4: ...3 4 M C INTERFACE SETTINGS 23 3 5 3 5 EXTERNAL MUTE INPUT 24 3 5 3 6 ALARM RELAY 24 3 5 3 7 ALARM RELAY TEST 25 3 5 3 8 FREQUENCY MIN 25 3 5 3 9 FREQUENCY MAX 25 3 5 3 10 FREQUENCY OFFSET 25 3 5 3 11...

Страница 5: ...and Parameter Tables 36 4 4 Web Browser Interface 38 4 4 1 Status Indicators 39 4 4 2 Navigation Bar 40 4 4 3 Main Area 40 4 5 Configuration Backup and Restore 40 4 5 1 Local Backup and Restore 41 4 5...

Страница 6: ......

Страница 7: ...The firmware versions can also be queried by the front panel menu SYSTEM CFG FIRMWARE VERSIONS or by the remote access 1 4 Abbreviations AC Alternating current BNC Bayonet Neill Concelman DC Direct C...

Страница 8: ...ned in EN 60950 1 6 Safety Instructions Please read this chapter carefully before you install and use this device from WORK Microwave To ensure your safety please make sure you observe the following i...

Страница 9: ...arm environment Pene tration by water increases the risk of electric shock 13 Prior to cleaning the product disconnect it completely from the power supply Use a soft nonlinting cloth to clean the prod...

Страница 10: ...3 1 Main Modules The Upconverter has a modular structure The unit consists of four main parts the Upconverter module the main power supply the master communication module Main controller and the user...

Страница 11: ...At this IF frequency a linear phase filter selects the correct mixer output signal This filter has a very low group delay distortion In the 2 nd mixer the IF signal at typically 2 45 GHz or 2 44 GHz...

Страница 12: ...7 90 8 40 140 2 58 2 44 10 34 10 84 7 90 8 40 X3 70 5 24 5 17 12 17 14 17 7 00 9 00 Ku 70 2 52 2 45 15 20 16 95 12 75 14 50 140 2 58 2 44 15 19 16 94 12 75 14 50 K 70 2 38 2 45 14 85 15 95 17 30 18 40...

Страница 13: ...tch 2 6 Rear Panel 1 5 9 7 12 10 2 3 4 14 11 6 8 13 Figure 6 Rear panel 1 Power Supply AC Input 100 240V including mains fuses 2 Alarm mute interface 3 USB 2 0 interface 4 M C remote control serial in...

Страница 14: ...serial interface RS485 RS232 5 M C Ethernet interface 10 100 MBit 6 Test output for local oscillator channel 2 fixed LO 7 IF input channel 2 8 Test output for local oscillator channel 2 MW LO 9 RF out...

Страница 15: ...enables the output of the con verter and a high level or open input disables the output of the converter Important When the Hardware Mute is enabled by software or front panel setting pin 4 and pin 9...

Страница 16: ...ta bits parity number of stop bits For the RS 485 twisted pair signals a 100 Ohm capacitive coupled 100 nF termination can be activated individually for the Data In RX and the Data Out TX signal pairs...

Страница 17: ...ype SMA 50 Ohm female With dual channel devices two RF outputs are available 2 7 7 Test Output of the MW Local Oscillator The signal of the microwave oscillator can be measured on the MW LO Out test o...

Страница 18: ...on options and details about this input 2 7 12 IF Input Connector The IF input signal is connected to the IF In connector at the rear panel The type of connector is BNC 50 Ohm or SMA 720 MHz IF 50 Ohm...

Страница 19: ...nabled or lot of remote access happens Green Flashing A remote user is active on the unit Off No remote user is active Warnings Orange A warning condition is active Off Normal operation Stored Alarms...

Страница 20: ...sing the Enter key activates the parameter for editing This is indicated with an arrow signal left and right of the parameter value A cursor shows the position within an alphanumeri cal parameter whic...

Страница 21: ...n nel Note For devices with 720 MHz IF frequency the RF center frequency of a 400 MHz band is set Therefore the adjustable frequency range is smaller then the usable frequency range This is shown in F...

Страница 22: ...l is lower than 6 dBm the converter is switched back to the internal reference 3 5 3 SYSTEM CFG The item SYSTEM CFG in the main menu allows access to the configuration and the monitoring of general se...

Страница 23: ...twisted pair RS485 RX signal data in chapter 2 7 4 This is only relevant if the interface type is set to RS485 The parameter values which can be selected are ON or OFF 3 5 3 4 5 M C PACKET DELAY The i...

Страница 24: ...P ACCESS in the M C INTERFACE SETTINGS submenu allows to activate or deacti vate the HTTP access over the Ethernet interface 3 5 3 4 17 ETH HTTPS ACCESS The item ETH HTTPS ACCESS in the M C INTERFACE...

Страница 25: ...user to adjust the displayed frequency value for special applications This value is set to zero after a factory reset The relation is as follows Displayed Frequency Converter Frequency Frequency Offse...

Страница 26: ...ON in the DATE TIME SETTINGS submenu allows to enable or disable the time server function If this function is enabled the internal clock will be synchronized with a time server by using the network ti...

Страница 27: ...converter After this menu item is selected the submenu can be activated by pressing the En ter key The submenu contains the following items Front panel base firmware XNA Front panel device firmware FC...

Страница 28: ...eference is configured to INTERNAL mode EXT Reference is configured to EXTERNAL mode AINT Reference is configured to AUTO mode and no external reference signal is detected AEXT Reference is configured...

Страница 29: ...3 28 12 27 11 26 10 25 Local Mode 9 24 External reference source 8 23 7 22 6 21 5 20 Synthesizer alarm 4 19 MW output module alarm 3 18 Amplifier module alarm 2 17 Reference alarm 1 16 Internal module...

Страница 30: ...he LED Stored Alarms on the front panel starts blinking If there are stored alarms it is possible with the Left and Right arrow keys to step through the alarm events With the Up or Down arrow key it i...

Страница 31: ...bus structured re mote control configuration with more than one controlled device connected to the same controller interface or when using the Ethernet TCP IP interface for remote control 4 2 2 MULTIP...

Страница 32: ...received command The response sent back has the following basic format HEADER device address OPCODE or error code response value if applicable TRAILER checksum If the controller executes a setting com...

Страница 33: ...dB ATA250 F 25 0 dB channel 1 ATA P TB Attenuation channel 2 This command is only available for dual channel devices Attenuation 0 30 dB ATB100 c 10 0 dB channel 2 ATB Q C Combination Command setting...

Страница 34: ...cription AZR101 z set configuration AZR g read value ZC Configuration Byte see Figure 16 0 to 127 AZC004 m AZC X ZI IP Address IP addr none AZI192 168 011 111 set IP address AZI read IP address AZI re...

Страница 35: ...emperatur AQT2 S Controller temperature AQT3 T Reference board temperature AQT4 U Synthesizer module temperature SA Read device and system status in hex None 0 1 ASA 0 Device Status ASA0 Device Status...

Страница 36: ...0 g reserved always 0 h Mute by external input 0 Normal 1 Mute 4 3 Command Parameter Tables Figure 14 Serial Interface Parameters for Command ZR Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Baud Ra...

Страница 37: ...1 Bit 0 0 reserved reserved reserved reserved reserved Interface Send Delay Interface Send Delay These bits set the transmission delay of the serial interfaces The answer on a received command can be...

Страница 38: ...configuration of the network mask and the gateway address The web browser needs to be set to Cookies enabled After getting access to the web server a login is required Figure 17 Login page Possible u...

Страница 39: ...Status indicators 2 Navigation bar 3 Main area The three areas are described in the following chapters 4 4 1 Status Indicators The two most important status indicators of the device are always displa...

Страница 40: ...des the configuration parameters for the converter unit Monitor The converter allows a variety of parameters to be monitored All important internal device parameters and operational parameters can be...

Страница 41: ...ce about 100kByte depends on the complexity of the configuration The configuration is written to the file config xml at the root directory of the flash disk The file contains the configuration in a XM...

Страница 42: ...can also be navigated by using the Browse button Choose a file with a valid configuration in XML format and with the name config xml The upload can be started by clicking on the Upload Configuration...

Страница 43: ...can be updated locally with the USB interface of the device A flash disk with the new firmware container file has to be attached to the device Please ensure the file converter update is located in the...

Страница 44: ...te for write Further the complete trap configuration is found here Up to 4 trap receivers can be defined with an internal name IP address UDP port default is 162 enable bit mask default is 0 set to 31...

Страница 45: ...onv2MCGateway 5 3 2 1 10 Sets and reads the gateway address conv2MCTCPPort 5 3 2 1 11 Sets and reads the TCP port number conv2MCUDPPort 5 3 2 1 12 Sets and reads the UDP port number conv2LoadDeviceSta...

Страница 46: ...nkServerTable 5 3 2 99 3 Reads the table of SNMP trap servers conv2FrontpanelTemperature 5 3 3 1 1 Reads the front panel temperature conv2ControllerTemperature 5 3 3 1 2 Reads the controller board tem...

Страница 47: ...rear panel 5 2 Service If a fault occurs with the device we kindly ask you to report the following to the factory support Model number and serial number Time in operation Description of failure Pleas...

Страница 48: ...e descriptions for repair Environment conditions Temperature Vibrations Frequency settings Other conditions Gain settings Item to be returned to WORK Microwave DDP Incoterms Date Name Signature Please...

Страница 49: ...Satellite Upconverter Manual WORK Microwave 49 49 V151207 6 Appendix 6 1 Technical Data A separate data sheet is attached at the end of this manual 6 2 Notes Place for own notes...

Отзывы: