Appendix

51

6.2

Electrical wiring diagram

Fig. 16

4.1

Ignition transformer

6

Temperature limiter, heat exchanger

6.1

Hot water NTC sensor (combi only)

9

Flue gas temperature limiter

18

Pump

32

Flame sensing electrode

33

Ignition electrode

36

Temperature sensor in CH flow

52

Solenoid valve 1

52.1

Solenoid valve 2

56

Gas valve CE 427

61

Reset button

84

Motor, 3-way valve

96

Microswitch, hydraulic switch (combi only)

135

Master switch

136

Temperature control for CH flow

151

Fuse, slow 2.5 A, AC 230 V

153

Transformer

161

Link 

226

Fan

300

Code plug

302

Earth connection

310

Temperature control for hot water

312

Fuse, slow T 1,6 A

313

Fuse, slow T 0,5 A

317

Digital display

328

Terminal block for AC 230 V Mains supply 

328.1

Link 

363

Indicator lamp for burner

364

Indicator lamp for power supply

365

“Chimney sweep” button

366

Service button

367

ECO button

400

Text display 

422

Connecting TR2

6

9

32

33

36

52.1

52

56

61

230 V

135

25 V

 230V/AC

153

136

151

1 2 4 7 8 9

161

M

226

300

L N

Ls

Ns

328

LR

302

310

312

313

317

363

364

365

366

ECO

367

4.1

328.1

6.1

18

84

96

M

400

4

3

F

M

6 720 610 602 - 02.1O

mains supply

422

o - orange   g - green    bl - black     r - red     p - purple

r
r

bl

bl
bl
bl

bl

o

o

o

o

g

g

p

p

p

Содержание ZSBR 7-30 RD 430i system

Страница 1: ...R 30 HE plus combi GC Number 41 311 79 ZWBR 11 35 R 35 HE plus combi GC Number 41 311 80 ZWBR 11 40 R 40 HE plus combi GC Number 41 311 81 ZSBR 7 30 RD 430i system GC Number 41 108 06 ZWBR 7 32 RD 532...

Страница 2: ...e not displayed 16 4 3 Notes on using the fault code tables 17 4 4 Error codes on the display 18 4 5 Faults that are not displayed 36 4 5 1 Appliance faults 36 4 5 2 Programmer faults 43 5 Replacement...

Страница 3: ...ot make any modifications to the appliance or carry out any repairs on it B Draw attention to the need for an annual service or maintenance contract if applicable Symbols Signal words indicate the ser...

Страница 4: ...ensor in CH flow 43 CH flow 63 Adjustable gas flow restrictor 64 Adjusting screw for min gas inlet flow volume 88 3 way valve 98 DHW flow switch combi 102 Inspection window 120 Fixing points 221 1 Flu...

Страница 5: ...On completion of the test sequence the appliance is ready for operation 2 2 Standard display The text display shows the time the CH flow tempera ture and the room temperature of TR2 location if fitted...

Страница 6: ...ed setting B Press the button The text display shows A T T E N T I O N Store settings B Press or to select yes or no B Press to confirm your selection The text display shows Please wait and the serv i...

Страница 7: ...k temp sensor2 not applicable 1 2 Code plug 8714411 XXX 0 255 1 4 Voltage at terminal 2 not applicable 1 5 Required flow temp for CH 0 99 C 1 8 Power set by module not applicable 1 9 Module detection...

Страница 8: ...applicable 4 2 Timer ch 1 heating blocked heat demand Timer ch 2 hot wat blocked heat demand 4 4 Heat demand heating yes no Heat demand stor tank system boiler yes no 4 5 Heat demand hot water yes no...

Страница 9: ...step heat 2 7 7 7 2 Antiblock map pump off on on 7 3 Air purge mode burner keeps off while air purge mode is on off on autom deactivat permanent on off 7 4 Actual map pump step 2 7 7 5 Map pump load...

Страница 10: ...ni mum output The text display shows MIn mode The 2 digit dis play alternates between the CH flow temperature and Max mode the appliance runs constantly at maxi mum output The text display shows Max m...

Страница 11: ...is displayed 3 9 Link 8 9 3 9 Link Ls Lr When supplied the appliance has a link fitted across terminals 8 9 Heat demand If that connection is opened e g by a limiter for an underfloor heating sys tem...

Страница 12: ...n air fan can be increased where problems with excessive flue lengths may interfere with ignition Areas with variable wind conditions may also benefit from this facility 6 6 Thermostore satisfied not...

Страница 13: ...setting is only active if function 7 0 Pump map heating is set to Pump step adjustable The factory setting is 7 1 Map pump step heat 7 Fig 5 Caracteristics 2 7 Caracteristics H Pressure Q Water circu...

Страница 14: ...that the condensa tion trap is filled when the appliance is first installed or after it has been shut down for a long period The con densation trap prevents flue gas escaping from the appliance into...

Страница 15: ...to four catego ries Category 1 The appliance is disabled until it has been switched off and then on again Category 2 The appliance is disabled until the cause of the fault has been eliminated Category...

Страница 16: ...t odour or is dark colour system boiler X 41 Text display fails to respond no display or display incorrect X X 41 Condensation in the flue pipe X X 41 Inadequate hot water outlet tem perature combi bo...

Страница 17: ...heck the flue is clear by testing the CO2 level If the appliance is locked button is flashing press the button If the fault has been rectified the appliance will then start up without indicating a fau...

Страница 18: ...rise see Installa tion Instructions B Turn ON the appliance A1 2 no 2 2 Audible bearing damage on pump yes B Power OFF the appliance B Disconnect the boiler electrical connection B Drain appliance B C...

Страница 19: ...ide Does the value match the ones described in table 7 page 50 yes B Make a note of the altered service function set tings see table 1 on page 7 in order to keep the altered values B Power OFF the app...

Страница 20: ...ance 2 2 B Check continuity on wiring to TR 2 Is there continuity yes 3 no B Replace or repair wiring and or connections B Turn ON the appliance After 90 sec A8 B Power OFF the appliance 3 3 B Check r...

Страница 21: ...DHW cylinder NTC con nector from PCB control board B Check resistance from connec tions 3 to 4 on the cable side Does the value match the ones described in table 7 page 50 yes B Make a note of the al...

Страница 22: ...number displayed with that shown in Appendix No number or incorrect number last three digits displayed yes 3 no 4 3 Code plug loose incorrect or defec tive B Power OFF the appliance B Fit code plug c...

Страница 23: ...Power OFF the appliance B Replace fan lead B Turn ON the appliance C1 3 3 Fan defective yes B Power OFF the appliance B Unplug the connection wire B Replace fan B Plug the connection wire B Turn ON th...

Страница 24: ...appliance d3 3 no 3 3 Terminal block defective B Power OFF the appliance B Disconnect the boiler electrical connection B Replace terminal strip B Reconnect the boiler electrical connection B Turn ON...

Страница 25: ...8 to 9 on the cable side Does the value match the ones described in table 7 page 50 yes B Make a note of the altered service function set tings see table 1 on page 7 in order to keep the altered valu...

Страница 26: ...d re pressurise see Installa tion Instructions B Reconnect the boiler electrical connection B Turn ON the appliance B Press restart the appliance E9 3 no 3 3 Lead disconnected from safety tem perature...

Страница 27: ...ce B Press restart the appliance E9 7 no B Connect CH flow safety temperature limiter B Turn ON the appliance 7 7 B Power OFF the appliance B Remove fuse SI 3 from appliance PCB control board and test...

Страница 28: ...ck supply pressure inform gas company if outside correct range B Is correct code plug fitted B Press restart the appliance EA 5 no 5 LPG models is the flow rate of the gas supply to the appliance corr...

Страница 29: ...as cock B Reconnect the boiler electrical connection B Reconnect the connectors B Turn ON the appliance B Check appliance for leaks B Press restart the appliance EA 9 9 Problem with flue B Open up hea...

Страница 30: ...e appliance B Engage ignition cable connector in switchbox B Turn ON the appliance B Press restart the appliance EA 14 14 Is the ignition electrical wire damaged yes B Power OFF the appliance B Change...

Страница 31: ...B Press restart the appliance EA 18 18 The PCB control board is damaged B Make a note of the altered service settings see table 1 on page 7 B Power OFF the appliance B Disconnect the boiler electrica...

Страница 32: ...t Settings Further options Service Display service param Other faults apart from F0 dis played yes B Deal with fault s displayed as instructed in rele vant fault table s no 4 4 flashing yes B Press bu...

Страница 33: ...7 2 2 Problem with flue B Check CO2 level in combustion air Is CO2 level above 0 2 yes B Check flue and repair or replace if necessary no 3 3 The PCB control board is damaged B Make a note of the alte...

Страница 34: ...gas cock B Reconnect the boiler electrical connection B Turn ON the appliance B Check appliance for leaks B Press restart the appliance FA 5 5 Check if the 20 pin connector lead assembly is damaged B...

Страница 35: ...etween text dis play module and Heatronic OK yes B Plug in connector FC 3 no B Replace text display module FC 3 3 Text display module defective B Replace text display module Fdand flashing Reset butto...

Страница 36: ...page 7 B Power OFF the appliance B Disconnect the boiler electrical connection B Change PCB control board B Reconnect the boiler electrical connection B Turn ON the appliance B Restore service setting...

Страница 37: ...rrectly fitted yes B Repair or replace components B Grease seal before fitting Make sure it is fitted in correct position Rumbling noises 5 no 5 5 B Measure CO2 levels CO2 levels in flue gas at min an...

Страница 38: ...h flue B Check CO2 level in combustion air Is CO2 level above 0 2 yes B Check flue and repair or replace if necessary Flue gas levels incorrect 4 no 4 4 Flue gas CO2 levels measured at min and max loa...

Страница 39: ...connector in switchbox B Turn ON the appliance B Press button Ignition poor 4 4 Is the ignition electrical wire damaged yes B Power OFF the appliance B Change the ignition electrical wire B Turn ON t...

Страница 40: ...nstructions Ignition poor 10 no 10 10 Burner not correctly fitted or defec tive B Power OFF the appliance B Turn off gas cock B Remove burner Cover fixings not tight or seal defective or not correctly...

Страница 41: ...m sacrificial anode with impressed current anode The conversion costs are payable by the opera tor Text display fails to respond no display or display incorrect Check Action Ignition lead is not fitte...

Страница 42: ...etween terminal 1 and terminal 3 230 V AC yes B Power OFF the appliance B Disconnect the boiler electrical connection B Change the 20 pin connector lead assembly B Reconnect the boiler electrical conn...

Страница 43: ...liance B Check appliance and system for water leaks and repair as necessary B Top up system B Turn ON the appliance B Activate menu option Show service parame ters B Select 7 3 Air purge mode select s...

Страница 44: ...temperature not reached integrated text display Check Action Set room temperature exceeded by large amount TR 2 Check Action 1 Do radiators get too hot yes B Decrease setting of Heating control 2 no...

Страница 45: ...all near window in draught on hollow wall etc B Select better installation location or B Fit external room thermostat Room temperature too high in Economy mode Check Action Building retains heat well...

Страница 46: ...the cov ers B Remove text display and unplug connector from the PCB B Remove screw holding power connector earth lead and remove earth lead B Remove two top fixing screws from the control box Fig 7 B...

Страница 47: ...ixing screws B Remove fan together with gas pipe and mixer unit B Separate the fan from the pipe and mixer unit by twisting the mixer unit to release it 4 Fig 9 5 3 Primary Heat exchanger Burner B Pow...

Страница 48: ...ove B Unscrew the pump union nuts Fig 12 After refitting B Fill system bleed and re pressurise see Installation Instructions 5 5 Clean condensation trap In order to prevent spillage of condensate the...

Страница 49: ...lation Instructions 5 8 Domestic Hot Water Heat Exchanger B Power OFF the appliance B Turn off service cocks B Drain appliance B Open pipe joints Fig 15 B Remove the domestic hot water heat exchanger...

Страница 50: ...sistance 20 124 900 40 53 290 60 24 890 80 12 550 100 6 777 120 3 873 140 2 328 160 1 455 180 948 200 540 Table 5 Outside temperature C Measurement tolerance 10 Resistance 20 2 392 16 2 088 12 1 811 8...

Страница 51: ...r CH flow 151 Fuse slow 2 5 A AC 230 V 153 Transformer 161 Link 226 Fan 300 Code plug 302 Earth connection 310 Temperature control for hot water 312 Fuse slow T 1 6 A 313 Fuse slow T 0 5 A 317 Digital...

Страница 52: ...22 55 Table 9 Component Order no Remarks Code plug included in Conversion kit G20 G31 8 714 411 062 0 ZWBR 7 30 Conversion kit G31 G20 8 714 411 059 0 Conversion kit G20 G31 8 714 411 114 0 ZWBR 11 35...

Страница 53: ...ccumulate in the boiler and remain active over long periods In order to limit the damage the source of the air con tamination must be located and sealed off If this is not possible the combustion air...

Страница 54: ...Supplied By www heating spares co Tel 0161 620 6677 7 181 465 347 05 01 54 Appendix...

Страница 55: ...Supplied By www heating spares co Tel 0161 620 6677 7 181 465 347 05 01 Appendix 55...

Страница 56: ...Supplied By www heating spares co Tel 0161 620 6677...

Отзывы: