Supplied By www.heating spares.co Tel. 0161 620 6677
7 181 465 347 (05.01)
39
Rectifying faults
Error Fd
Ignition too harsh, ignition poor
Check
Action
1.
B
Activate menu option Show serv-
ice parameters.
B
Select 5.1 Permanent ignition
(without Gas).
Continuous ignition (without gas)
OK?
yes:
↓
6.
no:
↓
2.
2.
Ignition lead connected to ignition
electrodes?
yes:
↓
3.
no:
B
Connect cable to ignition electrodes.
B
Press button
.
Ignition poor? 3.
3.
Ignition cable connector engaged in
switchbox?
yes:
↓
4.
no:
B
Power OFF the appliance.
B
Engage ignition cable connector in switchbox.
B
Turn ON the appliance.
B
Press button
.
Ignition poor? 4.
4.
Is the ignition electrical wire
damaged?
yes:
B
Power OFF the appliance.
B
Change the ignition electrical wire.
B
Turn ON the appliance.
B
Press button
.
Ignition poor? 5.
no:
↓
5.
5.
Electrode assembly defective?
B
Power OFF the appliance.
B
Remove electrode assembly.
Electrode assembly burnt out?
yes:
B
Replace electrode assembly.
B
Turn ON the appliance.
B
Press
, restart the appliance.
Ignition poor? 6.
no:
B
Refit electrode assembly.
B
Turn ON the appliance.
B
Press
, restart the appliance.
Ignition poor? 6.
6.
Does the gas supply type match the
specifications on the appliance iden-
tification plate?
yes:
↓
7.
no:
B
Convert appliance to correct gas type.
Ignition poor? 7.