Calling up information about the system

Sense ll – 6 720 812 775 (2014/10)

Calibrate room temperature sensor (Room temp. sen. adj.)

▶ Locate a suitable thermometer close to the controller so 

that they are both subject to the same heat influences.

▶ Keep heat sources such as direct sunlight and body heat, 

etc., away from the controller and the thermometer for one 
hour.

▶ Open the menu for sensor calibration.
▶ Turn the selector to set the correction value for the room 

temperature. For example, if the thermometer is showing a 
temperature 0.7 °C higher than the controller, increase the 
setting value by 0.7 K.

▶ Press the selector.

The controller operates with the modified settings.

Set correct time correction (Time correction)

Example of calculation of the value for time correction with a 
deviation of approx.  – 6 minutes per year (the control unit 
clock runs 6 minutes late):

  – 6 minutes per year =  – 360 seconds per year

1 year = 52 weeks

  – 360 seconds: 52 weeks =  – 6.92 seconds per week

Increase time correction to 7 seconds per week.

5.7

Adapting the settings to hybrid systems

Menu: 

Hybrid system

In an installation with a hybrid system, there are two different 
heat sources. One renewable energy heat source, i.e. 
geothermal, solar or biomass energy, and, in addition, a 
conventional heat source providing heat generated from oil, 
gas or electricity.

If a hybrid system or a hybrid appliance is installed, the 

Hybrid 

system

 menu is displayed. Depending on which hybrid system 

or hybrid appliance is being used and the associated 
assemblies or components, various settings can be made. For 
more information, see the technical documentation for the 
hybrid system or hybrid appliance (e.g. ODU 75 WPLSH).

6

Calling up information about the system

The current system values and the active operating conditions 
can be displayed easily via the info menu. No changes can be 
made in this menu.

The info menu is adapted to your system automatically. Some 
menu items are only available if the system has been set up 
accordingly and the controller has been set correctly 
(

 Chapter 2.2, page 4).

▶ If the standard display is active, press the info key to open 

the info menu.

▶ Turn the selector to select the required menu, e.g. 

DHW

.

▶ Press the selector to open the selected menu.
▶ Turn the selector to display more available information.
▶ Press the Back key to return to the previous menu level.
▶ Press and hold the Back key to return to the standard 

display.

Date

The holiday program, for example, runs 
according to this date. The current date of 
the week is also determined based on this 
date; this affects the time programs and 
thermal disinfection, for example. The date 
can be set in this menu.

Autom. time 
changeover

Activate or deactivate the automatic 
changeover between summer and winter 
time. If 

Yes

 is set, the time of day is 

automatically changed (from 02:00 to 
03:00 on the last Sunday in March and from 
03:00 to 02:00 on the last Sunday in 
October).

Display 
contrast

Change the contrast (for a clearer display)

Room temp. 
sen. adj.

Correction of the room temperature 
displayed by the controller by up to 



3 °C 

(

 Calibrate room temperature sensor 

(Room temp. sen. adj.), page 34).

Time 
correction

Time correction of the controller's internal 
clock in s/week (

 Set correct time 

correction (Time correction), page 34)

Standard 
display

Settings for the display of additional 
temperatures in the standard display

Internet 
password

Reset the personal password for the 
Internet connection (only available if a 
MB LAN2 communication module or an 
MX 25 appliance electronics with integrated 
communication module is installed). The 
next time you log in, e.g. using an App you 
will automatically be prompted to assign a 
new password.

Menu item

description

Table 30   General settings

Содержание Sense ll

Страница 1: ...UK IE Operating Instructions Advanced Weather Compensation Controller Sense ll 6 720 812 775 2014 10...

Страница 2: ...in menu 16 5 1 Main menu summary 17 5 2 Heat source settings 18 5 3 Adapting settings for heating system automatic mode 18 5 3 1Observewithconstantheatingcircuit e g swimming pool or ventilation unit...

Страница 3: ...ely Risk of scalding at the hot water draw off points If hot water temperatures above 60 C are set or if thermal disinfection is activated a mixer must be installed If in doubt ask your Installer 2 Pr...

Страница 4: ...ne of these modes The main control modes are Room temperature compensated The room temperature is controlled based on the measured room temperature The controller sets the heat output required from th...

Страница 5: ...is product For this see the contact address on the back cover of these instructions 2 6 Operation after power failure In the event of a power failure or periods with disconnected boiler no settings ar...

Страница 6: ...If a menu is open Press to call up more information about the current selection If the standard display is active Press to open the info menu Chapter 6 page 34 6 Back key Press to return to the previ...

Страница 7: ...ure for installation in heat source 2 Information line Display of time of day day of the week and date 3 Additional temperature display Display of an additional temperature outside temperature tempera...

Страница 8: ...off System with one heating circuit in summer mode heating off DHW heating active Chapter 5 3 4 page 25 HC2Summer off The displayed heating circuit operates in summer mode heating off DHW heating acti...

Страница 9: ...m are displayed for selection Wait a few seconds or press the selector The standard display refers to the heating circuit selected Note Your installer can set the heating circuits that are available i...

Страница 10: ...e display If manual operation with restricted duration is active the required room temperature and the duration of manual operation are displayed If it is too cold or too warm for you today Change the...

Страница 11: ...operation Setting a constant room temperature for a limited period of time Press and hold down the man key until the input field for the duration of manual operation is displayed Turn the selector to...

Страница 12: ...Press the selector twice to start the DHW heating The DHW heating is active immediately for the set duration Depending on the installed system it may be necessary to select a DHW system DHW system I o...

Страница 13: ...key lock is enabled the key symbol appears in the display Fig 2 5 page 7 To change the language of the display texts Set language Press the menu key to open the main menu Turn the selector to highligh...

Страница 14: ...enu Press the selector to select Deactivate emergency operation A pop up window is displayed in the display addressing the question whether you would like to deactivate the emergency operation If Yes...

Страница 15: ...15 Getting started Sense ll 6 720 812 775 2014 10 4 7 Bringing forward the switching time The function of the adv key always refers solely to the heating circuit that is active on the standard display...

Страница 16: ...ing My DHW time program Heating max temperature Reset prog DHW Circulation DHW max temp Operating Mode Heating Start frequency Temperature settings 2 My DHW circltn time prog Heating Thermal disinfect...

Страница 17: ...ly for increased comfort by bringing forward the switching times If you do this the required room temperature will be reached in advance of the switching time Recommended for high levels of comfort 25...

Страница 18: ...ilthesetting at the Sense I is changed again Menu Heating Menu item description Activate emergency operation Deactivate emergency operation In emergency operation heating and DHW heating are active Em...

Страница 19: ...r to open the Heating menu If Type of time program is set on Freely adjustable temperature press the selector to open the Setback threshold menu If two or more heating circuits are installed turn the...

Страница 20: ...for each day or group of days One of the two operating modes can be assigned to each switching time in automatic mode The minimum duration of a time slot between two switching times is 15 minutes Rese...

Страница 21: ...lector to highlight Time program Press the selector to open the Time program menu Turn the selector to highlight Activate time program Depending on the installed system it may be necessary to select a...

Страница 22: ...ystem top Turn the selector to highlight the operating mode temperature setting of a time slot Press the selector to activate the input field Turn the selector to select an operating mode heating or s...

Страница 23: ...ht Copy Press the selector A list of days of the week for which the time program should be overwritten with the selected day of the week is displayed for you to make a selection Turn and press the sel...

Страница 24: ...cted character The selected character is entered The input field for the next character in the text is enabled Turn the selector to enter more characters Press the Back key when you have finished maki...

Страница 25: ...m For constant heating circuits e g for a swimming pool or a ventilation unit the the switching between summer and winter modes is not available Menu item description Sum wint changeover In summer hea...

Страница 26: ...eating circuits Menu item description Start Cancel now After activation of the once only cylinder charging DHW is heated for the set duration to the set temperature When once only cylinder charging is...

Страница 27: ...mes is 15 minutes Reset prog The time program for the DHW system is reset to the default settings with this menu item Menu item description Table 23 Time program settings for DHW Operating the applian...

Страница 28: ...tor DHW heating is set to constant Depending on the installed system it may be necessary to select a DHW system Operating the appliance Result Table 24 Adapting the settings for DHW heating 6 720 815...

Страница 29: ...only in operation when DHW heating is active Depending on the installed system it may be necessary to select a DHW system Turn the selector to highlight Own time program and press the selector Thetime...

Страница 30: ...Auto is set here Start Cancel now Immediate start or termination of the thermal disinfection independent from the set day of the week Temperature Temperature of the entire DHW volume at thermal disin...

Страница 31: ...rcuits The Off setting deactivates the heating system completely for the selected heating circuits With the Setback setting the heating system runs in the selected heating circuits in the operating mo...

Страница 32: ...and end date of the holiday period opens The input field for entering the start day is highlighted Turn the selector to highlight the day months or year for the start or end date and press the select...

Страница 33: ...program Chapter 4 1 page 9 Press the man key Manual operation is activated The room temperature that is currently valid is shown in a pop up window in the lower part of the display Change the required...

Страница 34: ...conditions can be displayed easily via the info menu No changes can be made in this menu The info menu is adapted to your system automatically Some menu items are only available if the system has been...

Страница 35: ...pressure Actual temp Operating code Therm disinf DHW cyl Energy consumption 2 Solar 24h gas heating Solar sensors 24h elec heating Solar yield 24h gas DHW Outdoor temp 24h elec DHW Outdoor temp curve...

Страница 36: ...ld for last week solar yield for current week and total yield of solar system since the solar system was commissioned Table 33 Information about the solar system Operating the appliance Result Call up...

Страница 37: ...sult Table 34 Call up information about the solar system 6 720 815 237 55 1O Operating the appliance Result Calling up the outside temperature profile If the standard display is active press the info...

Страница 38: ...t recommended That would permit the walls to cool down too much During the heat up phase the ambient climate would be disturbed by the cool walls that would still radiate cold If you then raise theroo...

Страница 39: ...the residual heat that is not used is moved away via the heating circuit and the radiators Why does the heat pump work at night if the heating is negligible or very little There can be different reas...

Страница 40: ...ive room temperature fluctuations Temporary influenceofexternal heat on the room e g from solar exposure room lighting TV fireplace etc Contact Installer to install the controller at a suitable instal...

Страница 41: ...o switch to the standard display The continued presence of the fault is indicated in the info line If the fault is still active it can be restored to the display by pressing the Back key Thecausecanbe...

Страница 42: ...e time not yet set Set date time Prolonged loss of power supply Avoid voltage failures A11 3061 3064 No communication with heating circuit module 3061 heating circuit 1 3064 heating circuit 4 Check th...

Страница 43: ...ith the time program and an automatic changeover takes place between operating modes Mode The operating modes for heating are Heating and Setback They are depicted by the symbols and For a constant he...

Страница 44: ...is function heats up the hot water to a temperature in excess of 65 C This temperature is sufficient to kill off pathogens e g legionella Observe the anti scalding safety instructions Holiday program...

Страница 45: ...43 Domestic hot water 17 Adapt settings 27 System I and II 25 Temperature above 60 C 25 thermal disinfection 25 E Emergency mode 9 Environment disposal 43 F Faults Display in the event of a fault 41...

Страница 46: ...ed on outside temperature 25 Switch off the heating system 25 Switching time add 21 bring forward 10 15 delete 21 move 21 T Temperature 9 Actual DHW temperature 35 Actual flow temperature 34 DHW reduc...

Страница 47: ...47 Index Sense ll 6 720 812 775 2014 10...

Страница 48: ...9339 SPARES 0330 123 9779 LITERATURE 0330 123 9119 TRAINING 0330 123 0166 SALES 0330 123 9669 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 0330 123 9559 Worcester Bosch Group is a...

Отзывы: