29
Working with the main menu
Sense ll – 6 720 812 775 (2014/10)
The following table shows you how to adapt the settings for DHW circulation.
5.4.5 Thermal disinfection
Following thermal disinfection, the cylinder content slowly
cools back down to the set DHW temperature. Consequently,
the DHW temperature may briefly be higher than the selected
temperature.
The thermal disinfection safeguards the hygienic quality of the
DHW. The hot water is heated regularly to the set temperature.
This also kills off legionella, for example. Thermal disinfection
can be configured in this menu.
If a DHW cylinder is connected downstream of the low loss
header, it might not be possible to reach the temperature
necessary for thermal disinfection. For more information,
consult your Installer.
This menu is only available for DHW systems with DHW
cylinder.
Operating the appliance
Result
▶ Open the menu for the DHW settings (
▶ Turn the selector to highlight
Circulation
.
▶ Press the selector to open the
Circulation
menu.
The
Operating Mode
menu item is highlighted.
▶ Press the selector.
▶ Turn the selector to highlight
As DHW system I
or
II
and press the selector.
The controller operates with the modified settings. The DHW circulation pump is only
in operation when DHW heating is active. Depending on the installed system, it may
be necessary to select a DHW system.
▶ Turn the selector to highlight
Own time program
and press the selector.
The time program for circulation is independent of the time program for DHW heating.
The switching times can be set separately in the
Circulation
>
My circulation time
program
menu (operation as described in Chapter 5.3.2 starting on page 19). The
circulation is either switched on or off in the respective time slots.
▶ Turn the selector to highlight
Off
or
On
and press the selector.
The controller operates with the modified settings. The DHW circulation pump is
always off in the phases with
Off
.
Table 26 Settings for Adapt circulation
6 720 815 237-43.1O
6 720 815 237-44.1O
CAUTION:
Legionnaire's bacteria constitute a
health hazard!
▶ At low hot water temperatures thermal
disinfection or daily heating should be
activated
1)
.
1) Daily heating can be set by your installer in the service
menu.
If the thermal disinfection is set and activated
at the heat source, the settings at the
controller have no effect on the thermal
disinfection.
WARNING:
Risk of scalding!
If thermal disinfection has been activated to
avoid legionella, the hot water is heated once
to in excess of 65 °C (e.g. Thursday night at
02:00).
▶ Only schedule thermal disinfection for
periods outside normal usage times.
▶ Make sure that a mixer is installed. If in
doubt, ask your Installer.