PRE-COMMISSIONING CHECKS -
APPLIANCE
CAUTION: ISOLATE THE MAINS SUPPLIES
BEFORE STARTING ANY WORK AND
OBSERVE ALL RELEVANT SAFETY
PRECAUTIONS.
1
4
Check that the service and water pipes are
connected correctly.
4
Check that all unused sockets are capped.
2
4
Check that the oil supply is 28 sec
kerosene and that the pipework is
connected correctly to the oil pump.
4
Check that the burner is seated correctly
on its mounting flange and that the oil
pipe/s are not trapped in front of or
underneath the burner.
4
Turn on the main oil supply valve at the
tank, check the oil supply pipework and
connections. Rectify any leaks.
3
4
Check the flue is correctly fitted and the
connections are secure.
4
4
Check the condensate pipework is
correctly fitted and connected.
4
Check the condensate trap is filled with
water.
IMPORTANT: If the boiler is not to be
commissioned immediately then:
After successfully completing all of the
checks and any rectification work, close
the water valves, shut off the oil supply
and electrically isolate the boiler.
Complete the installation part of the
Guarantee Registration Card, and
complete a CD10 or equivalent, to
inform the LABC of the installation.
PRE-COMMISSIONING CHECKS -
APPLIANCE
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR CAMRAY KITCHEN 12/18-18/25-25/32
8 716 113 000a (01/07)
32
C
O
M
M
IS
S
IO
N
IN
G
Содержание 12/18
Страница 53: ...52 ...
Страница 54: ...53 ...
Страница 76: ...NOTES GREENSTAR CAMRAY KITCHEN 12 18 18 25 25 32 8 716 113 001a 01 07 17 NOTES NOTES ...