ELECTRICS
ELECTRICS
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR CAMRAY KITCHEN 12/18-18/25-25/32
8 716 113 000a (01/07)
30
IN
ST
AL
LA
TI
O
N
N1 1 2 3 4 5 6
7 8 9 10
F
H
G
1 2 3 4 5 6
Q
R
S
P
Brown
Blue
Blue
Brown
Gre
y
Blu
e
Yellow
/Gree
n
Orang
e
T
Brow
n
Orang
e
Yellow/Green
Grey
Blue
C
2
1
U
Orange
= EARTH
•
= LIVE
•
= NEUTRAL
DANGER - 230V:
ISOLATE THE MAINS ELECTRICITY
2 PORT VALVE CONTROL SET:
Key to components:
Q - CH ZONE VALVE.
R - ROOM THERMOSTAT.
S - CIRCULATING PUMP.
F - INTERNAL PROGRAMMER CONNECTOR.
G-TERMINAL CONNECTOR BLOCK.
H - LINK CONNECTOR.
T - HOT WATER CYLINDER THERMOSTAT.
U - HOT WATER VALVE.
P - OPTIONAL 230V WORCESTER
PROGRAMMER (fitted into fascia panel).
Terminator connector block (G):
4
Remove link 1 to 3.
4
Remove link 2 to 4.
4
Make link 3 to 4.
Optional 230V Worcester (P):
4
Set the pin on the rear of the programmer to
‘pumped’.
4
Remove the link plug (H).
4
Connect the plug from programmer (P) into
connector (F).