1.4. Adjustments and setting
The PORTI-S is set up at the factory to be appropriate for almost all users.
But if you want another specification to fit the printer at your system such as
change the baud rate, handshaking, parity check, as well as print density, please
contact to our development team or your dealer.
1.5. Using the printer
1. Control Panel
2. Button
1) MODE
Mode button is for use to change communication mode.
The communication mode is set to RAW IrDA mode when the power is on.
Press the mode button once, the mode will be changed to Standard IrDA
(Version 1.0) for Windows 98, please confirm the mode LED will twinkle
2 times.
Press the mode button twice, the mode will be changed to RS-232C mode
for Windows 98, please confirm the mode LED will twinkle 3 times.
All communication environment must be set with 9600 bps, 1 stop bit, no
parity, no flow control.
If you want to use the standard IrDA mode for Windows 98, check the your
computer's IrDA speed.
For example,
Your computer -> Start Menu -> Setting -> Control Panel -> IrDA -> Option
->
Communication Speed Limitation With 57600 bps
POWER
MODE
FEED
POWER LED
MODE LED
ERROR LED