![WOOSIM PORTI-S Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/woosim/porti-s/porti-s_operators-manual_996189032.webp)
(vertical printable area-vertical starting position).
7) The horizontal and vertical motion unit are specified by GS P.
Changing the horizontal or vertical motion unit does not affect the
current printing area.
8) The GS P command can change the horizontal (and vertical)
motion unit. However, the value cannot be less than the minimum
horizontal movement amount, and it must be in even units of
minimum horizontal movement amount.
9) Use the horizontal motion unit (x) for setting the horizontal starting
position and printing area width, and use the vertical motion unit
(y) for setting the vertical starting position and printing area height.
10) When the horizontal starting position, vertical starting position,
printing area width, and printing area height are defined as X, Y,
Dx, Dy respectively, the printing area is set as shown in the figure
below.
[Default]
xL = xH = yL = yH = 0
dxL = 0, dxH = 2, dyL = 126, dyH = 6
[Reference]
CAN, ESC L, ESC T, GS P
ESC \ nL nH
[Name]
Set relative print position
[Format]
ASCII
ESC
\
nL
nH
HEX
1B
5C
nL
nH
Decimal
27
92
nL
nH
[Range]
0 <= nL <= 255, 0 <= nH <= 255
[Description]
Set the print starting position based on the current position by using
the horizontal or vertical motion unit.
[Notes]
1) This command sets the distance from the current position to
(X,Y)
Paper
Dx
Dy
(X+Dx-1, Y+Dy-1)
Print area