Woolly Mammoth Stoves 2016/GB Issue 5 20/10/17
5
Technical Specification
Model
Output
Dimensions Overall -
mm
Dimensions
Firebox - mm
Weight-
kg
Fuel
Smoke
Exempt
Outlet Size -
mm
Outlet
Location
5
4.9kw
H450 x W370 x D440
H250x W250 x D290
75kg
Multifuel
Yes
125mm
Top & Rear
5WS
4.7kw
H480 x W470 x D333
H251x W385 x D210
66kg
Multifuel
Yes
125mm
Top & Rear
7
6.9kw
H550 x W590 x D410
H280x W480 x D270
120kg
Multifuel
Yes
150mm
Top & Rear
6
6kw
H1048 x W518 x D500
H410x W430 x D352
126kg
Wood
No
150mm
Top
7 XL
7kw
H1360 x W555 x D555
H580x W386 x D360
130kg
Wood
No
150mm
Top
Before Installing Your Woolly Mammoth Stove
Suitable ventilation must be provided for the installation of your Woolly Mammoth stove for safe,
efficient operation and compliance with Approved Document J of the building regulations. Air
vents must remain open at all times and be free of any obstructions. Extractor fans must not be
present in the same room as a heating appliance. Please refer to the building regulations for
minimum air vent sizes for your stove’s output.
Woolly Mammoth stoves must be installed on constructional hearths of non-combustible material
of at least 125mm depth, extending at least 150mm out from the stove either side and 300mm to
the front.
Space for fire
–
Distances to Combustible Materials
Model
Distance to Combustibles
–
Rear
(mm)
Distance to Combustibles
–
Side (mm)
Suitable For 12mm Hearth
5
450
450
NO
5WS
550
400
NO
7
450
450
NO
6
200
300
NO
7 XL
200
300
NO
Pre-existing chimneys must be in good condition and lined with a minimum 150mm internal
diameter flexible chimney liner.* If a chimney does not exist, a suitable insulated twin wall flue
system must be connected to the appliance again with a minimum 150mm internal diameter.* All
flue installations must be undertaken by a registered member of a government approved
competent persons scheme and under building control approval from your local authority. Failure
to do so will void the
Mammoth 5 Year warranty PLUS.
*Please note 125mm components allowed if stove is DEFRA approved
Chimney draw must be within specification for this stove to operate. With the chimney
warm, this must be between 1-2mm water gauge. Anything higher requires a draught
stabiliser to prevent over firing.