Woolly Mammoth WM 5 Скачать руководство пользователя страница 13

Woolly Mammoth Stoves 2016/GB Issue 5 20/10/17 

 

13 

 

 

Where a chimney has previously served an open fire, a second sweeping is recommended within a 
month of using your Woolly mammoth stove as the higher temperatures may dislodge previously 
embedded soot and tar deposits. 

When not in use (through the summer months), it is advisable to ensure the stove is clear of all 
ash and fuel and air in takes are left open to prevent condensation build up. 

Do not modify your Woolly Mammoth stove and ensure chimneys are clear before every heating 
season. 

Rope seals will require checking and potentially replacing annually. That is why your brand-new 
Woolly Mammoth stove has come supplied with 5yrs worth of rope seals. Please use a suitable 
heat resistant adhesive. 

Check all moveable parts regularly. 

Replacement Parts and Accessories

 

In addition to our market leading 5yr 

Mammoth warranty PLUS, 

for complete peace of mind and 

to ensure the ongoing enjoyment of your Woolly Mammoth stove, official replacement Woolly 
Mammoth stove components are readily available through our approved dealers. Please contact 
your local Woolly Mammoth supplier. 

Please refer to our warranty terms for components covered for a total of five years. 

To monitor the output and efficiency of your Woolly Mammoth stove, we recommend the use of a 
Woolly Mammoth Stove Thermometer, available from your local approved Woolly Mammoth 
dealer. 

To maximise the output and efficiency of your Woolly Mammoth stove, we recommend the use of 
a Woolly Mammoth Swift Original or Swift Plus Stove Fan, available from your local approved 
Woolly Mammoth dealer. 

 

 

 

 

Содержание WM 5

Страница 1: ...Woolly Mammoth Stoves 20 28 Albert Road Braintree Essex CM7 3JQ USER MANUAL PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE...

Страница 2: ...ation Lighting Instructions Page 8 9 Spring Autumn Syndrome Page 10 Over Under Firing Slow Combustion Ash Removal Page 11 Fuel Guide Page 12 13 Maintenance Page 14 Trouble Shooting Page 15 Fire Risk A...

Страница 3: ...or solid fuels only Due care must be taken when the stove is in operation as all external surfaces will become hot All local national and European standards must be complied with when installing any s...

Страница 4: ...cottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 In Northern Ireland appliances are exempted by publication on a list by the Department of Agriculture Environment and Rura...

Страница 5: ...s for your stove s output Woolly Mammoth stoves must be installed on constructional hearths of non combustible material of at least 125mm depth extending at least 150mm out from the stove either side...

Страница 6: ...become misplaced during transit The outlet collar and blanking plate are supplied with screws for securely fixing to the top and rear outlets Woolly Mammoth 5 5WS and 7 only Please check all componen...

Страница 7: ...Lighting Your Woolly Mammoth Stove Your new Woolly Mammoth stove is fitted as standard with an adjustable primary air intake controlled by the slider at the base of the model an adjustable secondary a...

Страница 8: ...r of small fires to bed in your new stove and ensure the longevity of the metal construction and any coatings You must avoid over firing Note that the Woolly Mammoth 5WS WideScreen WM5 WM7 have modifi...

Страница 9: ...n the outside temperature do not light the stove without clarifying that the air is travelling up rather than down the flue As mentioned previously a smell of soot is an indication that the flue is op...

Страница 10: ...e primary air control and reduce the secondary air control to no more than 25 This will allow the fuel to burn slowly whilst still emitting a comfortable heat Refuelling onto a low fire bed If there i...

Страница 11: ...and steadier than softer woods which will burn quickly and produce less heat We advise the use of Seasoned Hard Wood in log sizes which do not exceed the maximum log size We suggest that you refuel e...

Страница 12: ...ith the air controls or appliance dampers open can cause excessive smoke The appliance must not be operated with air controls appliance dampers or door left open except as directed in this user manual...

Страница 13: ...als Please use a suitable heat resistant adhesive Check all moveable parts regularly Replacement Parts and Accessories In addition to our market leading 5yr Mammoth warranty PLUS for complete peace of...

Страница 14: ...ls intact Are the glass retaining clips loose Is the correct fuel being used It is not unusual to require a draught stabilizer to reduce the draw on a stove due to excessive flue draught Blow Back If...

Страница 15: ...l During prolonged use of the stove the radial area will always be of an elevated temperature to the rest of the room Whilst the minimum distances are more than sufficient to fixed items care should b...

Страница 16: ...5yr Mammoth Warranty PLUS Your brand new Woolly Mammoth stove has been lovingly crafted and built to last and will be your companion for life if cared for and maintained correctly However in the extre...

Страница 17: ...on contained within the User Manual complies with all current building regulations and signed off by a member of the Competent Persons Scheme or Local Building Control Body Products must be installed...

Страница 18: ...US Please complete and return to supplier purchased from You will not be able to claim under the terms of the warranty without registering Name Address Telephone Number Email Address Woolly Mammoth 5...

Страница 19: ...Woolly Mammoth Stoves 2016 GB Issue 5 20 10 17 19 Installer Information Please complete for your records...

Страница 20: ...5 WM 5 Wood Ancit Nominal Heat Output kw 4 9 NA Total Efficiency 79 4 NA Mean CO Emission at 13 O2 0 19 NA Flue Gas Mass Flow g s 4 67 NA Mean Flue Gas Temperature C 244 c NA Height 450mm I Width 370...

Страница 21: ...Ancit Nominal Heat Output kw 4 4 4 7 Total Efficiency 73 77 Mean CO Emission at 13 O2 0 17 0 27 Flue Gas Mass Flow g s 5 97 6 62 Mean Flue Gas Temperature C 258 40 c 202 05 Height 480mm I Width 470mm...

Страница 22: ...nal Heat Output kw 6 9 N A Total Efficiency 76 1 N A Mean CO Emission at 13 O2 0 2393 N A Flue Gas Mass Flow g s 6 97 N A Mean Flue Gas Temperature C 274 2 c N A Height 550mm I Width 590mm I Depth 410...

Страница 23: ...Nominal Heat Output kw 6 N A Total Efficiency 78 N A Mean CO Emission at 13 O2 0 07 N A Flue Gas Mass Flow g s 6 12 N A Mean Flue Gas Temperature C 352 c N A Height 1048mm I Width 518mm I Depth 500mm...

Страница 24: ...t Nominal Heat Output kw 7 N A Total Efficiency 79 N A Mean CO Emission at 13 O2 0 09 N A Flue Gas Mass Flow g s 6 43 N A Mean Flue Gas Temperature C 366 c N A Height 1360mm I Width 555mm I Depth 555m...

Страница 25: ...Stove Secondary Air Control Unit Placement The SECONDARY AIR CONTROL SLIDER A is located within the SECONDARY AIR CONTROL TUNNEL B It is welded into place during the stove construction process The Tu...

Страница 26: ...t Placement Front From Above A 2nd Air Control B Air flow Tunnels The SECONDARY AIR CONTROL SLIDER A is located within the SECONDARY AIR CONTROL TUNNEL B It is welded into place during the stove const...

Страница 27: ...Woolly Mammoth Stoves 2016 GB Issue 5 20 10 17 27...

Страница 28: ...Woolly Mammoth Stoves 2016 GB Issue 5 20 10 17 28...

Страница 29: ...Woolly Mammoth Stoves 2016 GB Issue 5 20 10 17 29...

Отзывы: