Metal Developments Ltd reserve the right to change sizes and specifications without notice. E&OE
General Specifications - Inset Stove
Class 1: BS EN 13229:2001 + Amd 2:2004. For Intermittent use only.
Unsuitable for use in a shared flue system. Use only seasoned wood logs only.
Air Inlet grills must be so positioned that they are not liable to blockage.
Nominal Heat Output Kw
5
Space Heating Kw
5
Efficiency% (wood)
79
Efficiency% (solid fuel)
70.7
Co Emission @13% O2 (wood)
0.31
Co Emission @13% O2 (solid fuel)
0.14
Weight
Minimum Clearance From Combustibles
Above
350mm
Side
100mm
Recommended Refuelling Intervals (hours)
1.5
Maximum Log Length
280mm
Overall Height (Body in room)
620mm
Overall Height (Rear box in wall)
551mm
Overall Width (Body in room inc. top)
552mm
Overall Width (Rear box in wall)
400mm
Overall Depth (Body in room) inc. door)
106mm
Overall Depth (Rear box in wall)
310mm
Flue Outlet Size
127mm
Flue—Centre Line to rear of Convector Box
95mm (vert.)
Or 45 deg.
Stove Fire Boards
56
Side Board( mm) (2 Required)
142
320
Rear Board (mm)
282
280
148
290 x 147mm
Table 1
Содержание Firebright Inset