![Woodwarm Stoves Firebright Inset Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/woodwarm-stoves/firebright-inset/firebright-inset_installation-and-operating-instructions-manual_995939020.webp)
20
CHIMNEY FIRES
If the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does
occur turn the air control setting to the minimum, and tightly close the doors of the stove. This should cause the
chimney fire to go out in which case the control should be kept at the minimum setting until the fire in the stove
has gone out. The chimney and flue ways should then be cleaned. If the chimney fire does not go out when the
above action is taken then the fire brigade should be called immediately.
After a chimney fire the chimney should be carefully examined for any damage. Expert advice should be sought if
necessary.
FAULT FINDING
A) Stove smokes on lighting or when fire door is opened
Flue ways blocked - sweep chimney and flue.
Baffle incorrectly fitted.
Adverse wind conditions, or down draught - check height and diameter of chimney.
Flue not connected (or not sealed) to appliance or chimney .
B) Stove burns fuel too fast
Air controls open.
If the above are closed then excess air may be entering from elsewhere.
Check if door glass and ash pit door rope seals are damaged or not seating.
Check all flue connections are airtight. Check if flue blanking plate is airtight.
Go through installation procedures and cautionary notes.
Chimney draw too fast - fit flue stabiliser.
C) Door glass sooting up
Allow stove to reach body temperature before closing air wash.
Primary air inlet open, whilst Secondary air control is shut.
Use bottom air as choke only - i.e.
minimal use.
Fuel load too close to the door.
FUME EMISSION
WARNING NOTE: WHEN PROPERLY INSTALLED AND OPERATED THIS APPLIANCE WILL NOT EMIT
FUMES OR SMOKE TO THE ROOM. OCCASIONAL FUMES FROM DE-ASHING AND RE-FUELLING MAY
OCCUR. PERSISTENT FUME OR SMOKE EMISSION TO THE ROOM MUST NOT BE TOLERATED.
IF EMISSION DOES PERSIST THEN THE FOLLOWING IMMEDIATE ACTION MUST BE TAKEN.
A
OPEN ALL DOORS AND WINDOWS TO VENTILATE THE ROOM
B
LET THE FUEL OUT AND SAFELY DISPOSE OF FUEL FROM THE APPLIANCE
C
CHECK FOR FLUE OR CHIMNEY BLOCKAGE AND CLEAN IF NECESSARY
D
DO NOT ATTEMPT TO RELIGHT THE FIRE UNTIL THE CAUSE OF THE FUMES HAS BEEN
IDENTIFIED, IF NECESSARY SEEK PROFESSIONAL ADVICE
Содержание Firebright Inset