CHIMNEY FIRES

 

 
 

If the chimney is thoroughly and regularly swept, chimney fires should not occur. However, if a chimney fire does 
occur turn the air control setting to the minimum, and tightly close the doors of the stove. This should cause the 
chimney fire to go out in which case the control should be kept at the minimum setting until the fire in the stove 
has gone out. The chimney and flue ways should then be cleaned. If the chimney fire does not go out when the 
above action is taken then the fire brigade should be called immediately. 
 
After a chimney fire the chimney should be carefully examined for any damage. Expert advice should be sought if 
necessary. 

 

 

FAULT  FINDING

 

  

A)   Stove smokes on lighting or when fire door is opened

 

Flue ways blocked - sweep chimney and flue. 
Baffle incorrectly fitted. 
Adverse wind conditions, or down draught - check height and diameter of chimney. 
Flue not connected (or not sealed) to appliance or chimney . 
 

B)   Stove burns fuel too fast

 

 

 

Air controls open. 
If the above are closed then excess air may be entering from elsewhere. 
Check if door glass and ash pit door rope seals are damaged or not seating. 
Check all flue connections are airtight. Check if flue blanking plate is airtight.  
Go through installation procedures and cautionary notes. 
Chimney draw too fast - fit flue stabiliser. 
 

C)   Door glass sooting up 

Allow stove to reach body temperature before closing air wash. 
Primary air inlet open,  whilst Secondary air control is shut. 
Use bottom air as choke only - i.e. 

 minimal use.

 

Fuel load too close to the door. 

FUME  EMISSION 

 
WARNING NOTE: WHEN PROPERLY INSTALLED AND OPERATED THIS APPLIANCE WILL NOT EMIT 
FUMES OR SMOKE TO THE ROOM.  OCCASIONAL FUMES FROM DE-ASHING AND RE-FUELLING MAY 
OCCUR.  PERSISTENT FUME OR SMOKE EMISSION TO THE ROOM MUST NOT BE TOLERATED.   
IF EMISSION DOES PERSIST THEN THE FOLLOWING IMMEDIATE ACTION MUST BE TAKEN. 
 

OPEN ALL DOORS AND WINDOWS TO VENTILATE THE ROOM 

 

LET THE FUEL OUT AND SAFELY DISPOSE OF FUEL FROM THE APPLIANCE 

 

CHECK FOR FLUE OR CHIMNEY BLOCKAGE AND CLEAN IF NECESSARY 

 

DO  NOT  ATTEMPT TO RELIGHT THE FIRE UNTIL THE CAUSE OF THE FUMES HAS BEEN  

          IDENTIFIED,  IF NECESSARY SEEK PROFESSIONAL ADVICE 

Содержание Firebright Inset

Страница 1: ...nd Guarantee Document A new era in clean effective multi fuel stoves Woodwarm Stoves Woodwarm Stoves Serial Number Also detailed on data plate located on the back of the stove door Please quote when m...

Страница 2: ...How Clean Burn Works Lighting Initial Lighting curing paint Stove Air Controls Running The Stove Extended Burning Things To Avoid Operation of the grate Daily Routine Maintenance and Servicing Chimney...

Страница 3: ...id fuel 70 7 Co Emission 13 O2 wood 0 31 Co Emission 13 O2 solid fuel 0 14 Weight Minimum Clearance From Combustibles Above 350mm Side 100mm Recommended Refuelling Intervals hours 1 5 Maximum Log Leng...

Страница 4: ...he skin In cases of con tact wash off with plenty of water Electrical If any electrical components are used in the installation they should be installed in accordance with the manufacturers installati...

Страница 5: ...r nearest professional installer or the Building Inspector at your local council Whichever chimney option you choose to use DO NOT FORGET TO POSITION A CLEANING ACCESS if applicable in your flue and c...

Страница 6: ...le rooflight dormer window or other opening Note 3 At least 1000mm above the top of the opening D within 2300mm of an adjoin ing or adjacent building whether or not beyond the boundary Note 3 at least...

Страница 7: ...Flue Outlet Configuration Fig 2 Minimum 4 5mtrs Flexible Liner Rain Cap Fig 2b Fig 2a Flue Vent M A Adaptor Vertical Outlet position Solid flue sec tion to prevent Brush damage 45 Degree Outlet positi...

Страница 8: ...ily by rotating them fully open then lifting each one out of the grate link bar outwards and upwards SEPARATE THE STOVE AND CASSETTE BOX Separate the stove from the cassette box by removing the 2no M8...

Страница 9: ...ette box In this case the opening was high enough to allow insulation to be fitted around the flue after the Cassette was installed The Cassette Box will need fixing in to avoid it moving out of posit...

Страница 10: ...a consumable product The replacement sizes are provided under Stove Fire boards on table 1 page 3 Fig 7 Fig 8 Fig 9 With the Cassette Box the Adaptor and it s 2no M8 threads should come through their...

Страница 11: ...oard Fig 10 BAFFLE The smoke baffle sits on the Fire boards as shown in Fig 11 and Fig 12 Ensure baffle seats squarely on boards and is pushed fully to the rear Fig 11 How to insert Baffle through doo...

Страница 12: ...making an even contact with the stove body when the door is closed Your Woodwarm stove is supplied with a heat resistant glove to operate the door handle e t c when hot Turn handle to clockwise to op...

Страница 13: ...ove can then be lit and checked to ensure that smoke is taken from the appliance up the chimney and emitted safely The customer should be advised on the use of the appliance On completion of the insta...

Страница 14: ...sh before the fuel is up to temperature and or wood fuel is too wet If a routine is established of hard burning on secondary air only for 20 minutes at each end of the day this will assist in keeping...

Страница 15: ...l or dry wood Dry wood means that it has not more than 20 moisture content If these operating instructions are fol lowed correctly no significant smoke will be produced Burning wet 20 moisture content...

Страница 16: ...cool down prior Primary Air Control Under Grate Air Secondary Air Control Airwash Air STOVE AIR CONTROLS Fig 17 OPERATING INSTRUCTIONS Before lighting check with the installer that the work and check...

Страница 17: ...o a low or cool bed of embers as excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that a new fuel charge will ignite in a reasonab...

Страница 18: ...shpan Too much riddling poking can result in unburnt fuel being emptied into the ash pan and should be avoided Any clinkers should be regularly removed from the fire bed The ashpan should be emptied r...

Страница 19: ...boards and seals and replace if deteriorated Remove and clean over the baffle and clear flue ways more often if burning solid fuel A visit from the chimney sweep will remove the small amount of ash du...

Страница 20: ...n If the above are closed then excess air may be entering from elsewhere Check if door glass and ash pit door rope seals are damaged or not seating Check all flue connections are airtight Check if flu...

Страница 21: ...rantee Form this will help maintain our records and assist us in identifying your stove in the unlikely event of any problem occurring and also when you need to order any spare parts IMPORTANT READ TH...

Страница 22: ...er INSTALLERS DETAILS Name Address Phone Number HETAS Registration Number SPARE PARTS Use only Metal Developments Ltd approved replacement parts 14mm Main Fire Door Rope Door Glass Ladder Rope Door Gl...

Страница 23: ...k Stone Staffordshire ST15 OSR Tel 01785 811732 www chimneyworks co uk The National Association Of Chimney Engineers N A C E Ltd PO Box 849 Metheringham Lincoln Lincolnshire LN4 3WU Tel 01526 322555 F...

Страница 24: ...24 01 06 13 Version INSSE...

Отзывы: