Woodwarm Stoves Firebright Inset Скачать руководство пользователя страница 21

21 

THE WOODWARM STOVES GUARANTEE 

 
Metal Developments Ltd offer a five year guarantee which covers the main structure of the stove  
including the construction and quality of workmanship. 
 
In the unlikely event of any failure we will replace any defective part free of charge, labour cost  
excluded. 
 
This guarantee is invalid if the stove is not assembled, installed or operated as per these  
instructions or does not comply with current building regulations and any regional legislation in force 
at the time. 
 
Metal Developments Ltd does not guarantee the onsite assembly, installation or operation of the 
stove. Please seek advise from your stove supplier / installer for any relevant guarantees applicable 
to the installation. 
 
Metal Developments Ltd will not be held liable for any consequential or incidental loss, damage or 
injury, however caused. 
 
Claims under this guarantee should be first made through your Woodwarm Stove retailer. 
 
This guarantee is only applicable in the UK. 
 
Nothing in this guarantee shall effect your statutory rights. 
 

Exclusions 
 

The following consumable parts are not covered by this guarantee : - 
 

Swivel Fire Bars, Logguard, Baffle Plate, Operating Tool, Fire Boards, Glass Panels and Door 
Seals. 
 
Paint 

is also excluded from the guarantee as it will eventually deteriorate due to the normal working 

of the stove. 
 
Your assistance is requested by filling in and returning the product Registration and Guarantee 
Form, this will help maintain our records and assist us in identifying your stove in the unlikely event 
of any problem occurring and also when you need to order any spare parts. 
 

 

                      

      

IMPORTANT—READ THIS

 

 
                            

MAXIMUM  OPERATING TEMPERATURE

 

                                

 

The stove body is designed to run up to a maximum temperature not  exceeding

 

650F or 350C, beyond 

which damage can occur.  

The outside body temperature may not reflect this but we still recommend the use of a 

stove thermometer available from your dealer, in order to make a judgement as to this condition. 
 

There are 3 possible causes for stoves over-heating :- 
1. 

Air controls, in particular the Primary ( under grate air), left  too far open for too long.  

You will hear 

the stove drawing too hard and the fuel bed will become White hot as will the surrounding metal of 
the stove. 

Do not leave the stove unattended  with air controls too far open. 

2.  

The fire door has been left open or the rope seal is worn, damaged or missing. This should be re-
placed if necessary or can be pulled out, adjusted and  easily re-placed. 

3. 

Excessive chimney draw (the minimum flue draft for nominal heat output is:-  not exceeding 0.15 
mbar  (0.06" water  gauge)).  If it is high use remedial action;  either the fitting of a flue stabiliser to 
the flue as close to the appliance as is aesthetically  possible, the fitting of  a flue damper in the 
chimney, or a chimney cowl.  (Ask your dealer or contact us for details). 

Chipboard and other composite wood-type materials contain corrosive additives, as do sulphurous coal 
products especially when mixed with wet wood, these may etch and permanently damage the surface of 
the glass. 

Содержание Firebright Inset

Страница 1: ...nd Guarantee Document A new era in clean effective multi fuel stoves Woodwarm Stoves Woodwarm Stoves Serial Number Also detailed on data plate located on the back of the stove door Please quote when m...

Страница 2: ...How Clean Burn Works Lighting Initial Lighting curing paint Stove Air Controls Running The Stove Extended Burning Things To Avoid Operation of the grate Daily Routine Maintenance and Servicing Chimney...

Страница 3: ...id fuel 70 7 Co Emission 13 O2 wood 0 31 Co Emission 13 O2 solid fuel 0 14 Weight Minimum Clearance From Combustibles Above 350mm Side 100mm Recommended Refuelling Intervals hours 1 5 Maximum Log Leng...

Страница 4: ...he skin In cases of con tact wash off with plenty of water Electrical If any electrical components are used in the installation they should be installed in accordance with the manufacturers installati...

Страница 5: ...r nearest professional installer or the Building Inspector at your local council Whichever chimney option you choose to use DO NOT FORGET TO POSITION A CLEANING ACCESS if applicable in your flue and c...

Страница 6: ...le rooflight dormer window or other opening Note 3 At least 1000mm above the top of the opening D within 2300mm of an adjoin ing or adjacent building whether or not beyond the boundary Note 3 at least...

Страница 7: ...Flue Outlet Configuration Fig 2 Minimum 4 5mtrs Flexible Liner Rain Cap Fig 2b Fig 2a Flue Vent M A Adaptor Vertical Outlet position Solid flue sec tion to prevent Brush damage 45 Degree Outlet positi...

Страница 8: ...ily by rotating them fully open then lifting each one out of the grate link bar outwards and upwards SEPARATE THE STOVE AND CASSETTE BOX Separate the stove from the cassette box by removing the 2no M8...

Страница 9: ...ette box In this case the opening was high enough to allow insulation to be fitted around the flue after the Cassette was installed The Cassette Box will need fixing in to avoid it moving out of posit...

Страница 10: ...a consumable product The replacement sizes are provided under Stove Fire boards on table 1 page 3 Fig 7 Fig 8 Fig 9 With the Cassette Box the Adaptor and it s 2no M8 threads should come through their...

Страница 11: ...oard Fig 10 BAFFLE The smoke baffle sits on the Fire boards as shown in Fig 11 and Fig 12 Ensure baffle seats squarely on boards and is pushed fully to the rear Fig 11 How to insert Baffle through doo...

Страница 12: ...making an even contact with the stove body when the door is closed Your Woodwarm stove is supplied with a heat resistant glove to operate the door handle e t c when hot Turn handle to clockwise to op...

Страница 13: ...ove can then be lit and checked to ensure that smoke is taken from the appliance up the chimney and emitted safely The customer should be advised on the use of the appliance On completion of the insta...

Страница 14: ...sh before the fuel is up to temperature and or wood fuel is too wet If a routine is established of hard burning on secondary air only for 20 minutes at each end of the day this will assist in keeping...

Страница 15: ...l or dry wood Dry wood means that it has not more than 20 moisture content If these operating instructions are fol lowed correctly no significant smoke will be produced Burning wet 20 moisture content...

Страница 16: ...cool down prior Primary Air Control Under Grate Air Secondary Air Control Airwash Air STOVE AIR CONTROLS Fig 17 OPERATING INSTRUCTIONS Before lighting check with the installer that the work and check...

Страница 17: ...o a low or cool bed of embers as excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that a new fuel charge will ignite in a reasonab...

Страница 18: ...shpan Too much riddling poking can result in unburnt fuel being emptied into the ash pan and should be avoided Any clinkers should be regularly removed from the fire bed The ashpan should be emptied r...

Страница 19: ...boards and seals and replace if deteriorated Remove and clean over the baffle and clear flue ways more often if burning solid fuel A visit from the chimney sweep will remove the small amount of ash du...

Страница 20: ...n If the above are closed then excess air may be entering from elsewhere Check if door glass and ash pit door rope seals are damaged or not seating Check all flue connections are airtight Check if flu...

Страница 21: ...rantee Form this will help maintain our records and assist us in identifying your stove in the unlikely event of any problem occurring and also when you need to order any spare parts IMPORTANT READ TH...

Страница 22: ...er INSTALLERS DETAILS Name Address Phone Number HETAS Registration Number SPARE PARTS Use only Metal Developments Ltd approved replacement parts 14mm Main Fire Door Rope Door Glass Ladder Rope Door Gl...

Страница 23: ...k Stone Staffordshire ST15 OSR Tel 01785 811732 www chimneyworks co uk The National Association Of Chimney Engineers N A C E Ltd PO Box 849 Metheringham Lincoln Lincolnshire LN4 3WU Tel 01526 322555 F...

Страница 24: ...24 01 06 13 Version INSSE...

Отзывы: