ProTech 203 Overspeed Protection System
Manual 85204
2
Woodward
Table 1-1. De-energize-to-Trip ProTech Models
Part No.
UNIT A
UNIT B
UNIT C
9907-147
24 Vdc
24 Vdc
24 Vdc
9907-149
120 Vac/dc
120 Vac/dc
120 Vac/dc
9907-151
220 Vac
220 Vac
220 Vac
Table 1-2. Energize-to-Trip ProTech Models
Part No.
UNIT A
UNIT B
UNIT C
9907-146
24 Vdc
24 Vdc
24 Vdc
9907-148
120 Vac/dc
120 Vac/dc
120 Vac/dc
9907-150
220 Vac
220 Vac
220 Vac
Table 1-3. Voltage Ranges
Input Power Requirements Per Kernel
24 Vdc = 18–32 Vdc, 5.12 W
120 Vac/dc = 88–132 Vac, 12.5 VA
90–150Vdc, 4.77 W
220 Vac = 180–264 Vac, 16.4 VA
References
The following Woodward publications contain additional product or installation
information on overspeed protection systems and related components.
82715
Guide for Handling and Protection: Electronic Controls, Printed
Circuit Boards, Modules
82510
Magnetic Pickups and Proximity Switches for Electronic Governors
50532
EMI Control for Electronic Governing Systems
Содержание ProTech 203