Mounting
The valve housing has four 6.9 mm (0.27 inch) through-holes in a square 41.1
mm (1.62 inch) pattern for mounting.
Figure 3-3. Valve Outline Drawing
The gas inlet is a 0.25 inch (6.4 mm) NPT threaded fitting and the outlet is 3/8
inch (9.5 mm) NPT.
Environmental Specifications
Temperature:
–40 to +70 °C (–40 to +158 °F)
Proof pressure:
1379 kPa (200 psig)
Coil
Resistance: 14