easYgen-1000 Series - Genset Control
© Woodward
Page 17/57
Term. Description
Type
Hardware
3
3
G
1
S/S
3
3
GCB
G
1
S/S
op
en
GCB
3
3
G
1
S/S
ope
n/
clos
e
3
1
MCB
GCB
3
3
G
1
S/S
op
en
/c
lo
s
e
{0}
on page 18
{1o}
{1oc}
{2oc}
on page 21
30 Relay
[R1]
Relay
Make contact (NO)
LogMa
#R
LogMa
#R
LogMa
#R
LogMa
#R
31
Relay [R2]
Make contact (NO)
LogMa
#R
LogMa
#R
LogMa
#R
LogMa
#R
32
Relay [R3]
Make contact (NO)
Crank
33
Relay [R4]
Make contact (NO)
Diesel: Fuel magnet; Gas: Gas valve
34
Relay [R5]
Make contact (NO)
LogMa
#R
35 Common
Common
9
9
9
9
36
Relay [R6]
Relay
Make contact (NO)
Auxiliary services
37 Main
contact
38
Relay [R7]
Relay
Make contact (NO)
LogMa
#R
Command: open GCB
39 Main
contact
40
Relay [R8]
Relay
Make contact (NO)
LogMa
#R
LogMa
#R
LogMa
#R
Command:
close MCB
41 Main
contact
42
Relay [R9]
Relay
Make contact (NO)
LogMa
#R
LogMa
#R
LogMa
#R
Command:
open MCB
43 Main
contact
44
Relay [R10]
Relay
Make contact (NO)
LogMa
#R
LogMa
#R
Command: close GCB
45 Main
contact
46
Relay [R11]
Relay
Make contact (NO)
Ready for operation /
LogMa
#R
47 Main
contact
48
Power supply
Supply
0 Vdc
9
9
9
9
49 12/24
Vdc
50 Common
Input
Common
9
9
9
9
51
Discrete input [D1]
Contact
LogMa
#D
LogMa
#D
LogMa
#D
LogMa
#D
52
Discrete input [D2]
Contact
LogMa
#D
LogMa
#D
LogMa
#D
LogMa
#D
53
Discrete input [D3]
Contact
LogMa
#D
LogMa
#D
LogMa
#D
LogMa
#D
54
Discrete input [D4]
Contact
LogMa
#D
LogMa
#D
LogMa
#D
LogMa
#D
55
Discrete input [D5]
Contact
LogMa
#D
LogMa
#D
LogMa
#D
LogMa
#D
56
Discrete input [D6]
Contact
LogMa
#D
LogMa
#D
LogMa
#D
#1
57
Discrete input [D7]
Contact
LogMa
#D
LogMa
#D
LogMa
#D
Repl:MCB
58
Discrete input [D8]
Contact
LogMa
#D
LogMa
#D
Reply: GCB is closed
#R -
LogMa
- Relay output (via the function
LogicsManager
the relays can be programmed freely)
#D -
LogMa
- Discrete input (the discrete input may be used in the
LogicsManager
if the alarm class is configured to "Control")
#1 - if the parameter "Enable MCB" is configured to "Always" this DI may be used as alarm input (
LogMa
#D
)
if the parameter "Enable MCB" is configured to "DI6" the MCB may be enabled by energizing this DI
Repl:MCB..Reply: MCB is closed
Table 5-2: Terminal overview, part 2