Other Available Pipe:
6
5
/
8
" x 6" Straight Pipe
908
908B
6
5
/
8
" x 9" Straight Pipe
907
907B
6
5
/
8
" x 12" Straight Pipe
906
906B
6
5
/
8
" x 24" Straight Pipe
904
904B
6
5
/
8
" x 36" Straight Pipe
903
903B
6
5
/
8
" x 48" Straight Pipe
902
902B
6
5
/
8
" x 11"- 14-5/8" Adjustable
911
911B
6
5
/
8
" x 17 - 24" Adjustable Pipe
917
917B
6
5
/
8
" x 45 Degree Elbow
945
945B
6
5
/
8
" x 90 Degree Elbow
990
990B
6
5
/
8
" x 90 Degree Adj. Elbow
990G
990BG
6
5
/
8
" x 45 Degree Adj. Elbow
945G
945BG
Horizontal Termination Cap
984
*
Snorkel Termination Cap
36" Rise
981
*
14" Rise
982
*
Vinyl Siding Standoff
950
*
6
5
/
8
" Wall Thimble
942
*
Wall Thimble Cover
940
940B
Cathedral Ceiling Support Box
941
*
Restrictor Disc (top vent)
929
*
Storm Collar
953
*
Adj Roof Flashing (0/12-6/12 pitch)
943
*
Adj Roof Flashing
(7/12-12/12 steep pitch)
943S
*
Vertical Termination Cap
980
*
Vertical Termination Cap
991
*
Vertical Termination Cap
930
*
* Galvanized Only
WARNING: Due to high temperatures, the Franklin Gas Fireplace
should be placed out of traffic and away from furniture, draperies and
other combustibles.
The Franklin Gas Fireplace is approved for venting in five
configurations:
(1) Up vertically as much as 20’ and then elbow through an
outside wall with a maximum horizontal run of 4’.
(2) Straight out the back through an outside wall and into a
snorkel termination cap (maximum 4’ horizontal run, with
1/4” rise per foot of run).
(3) Up vertically through the roof, with maximum rise of 24’.
(4) Into an existing fireplace and chimney (maximum height of
24’).
(5) Into an existing masonry or prefabricated metal chimney
(maximum height of 24’).
NOTE: Details for these five configurations start on page 6.
Clearances inside the house for these three basic installations are
indicated in the illustrations which follow.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 4
---------------------------------------------------------------------------------------------------------------------------------
Approved Clearances for Inside Locations
Illustration 4.2
All approved
Simpson Dura-Vent Pipe has an
inside passage to vent exhaust
gasses, and an outside passage
used to bring in fresh air for
combustion.
5. APPROVED CLEARANCES FOR INSIDE LOCATIONS
CLEARANCES TO
COMBUSTIBLE
MATERIALS
Front ................................30"
Sides ..................................8"
Rear of Fireplace .............10"
Corners ..............................2"
Rear of 90 Degree Elbow..2"
WARNING: This unit
must be installed by a
qualified gas technician in
accordance with local codes or
in the absence of local codes,
with the most current edition
of the National Fuel Gas Code
ANSI Z223.1/NFPA 54.