thermocouple are properly connected to both the pilot
assembly and gas controller (see illustration 9.5).

8. Check that the piezo wire is connected to the pilot assembly

and igniter button (see illustration 9.5). Press the Red
Ignition Button to test for spark in the Firebox near the pilot.

CAUTION: Sheet metal edges are sharp. Please handle carefully

1. INSTALLING THE LOGSET

Remove the front casting and glass front – see illustrations 9.1

and 9.3 for details.  Place the Logset over the five positioning tabs
on the Burner Pan. Push it as far back as it will go toward the rear
of the Firebox.

If you own a Natural Gas Fireplace then your logset will sit on

top of the Air Shield and not directly on the tabs. The air shield
should sit flat on the (2) front tabs. The sides must be pushed
down into position. Be sure that the sides of the air shield do not
hang up on the inside walls of the firebox.

Make sure that the front edge of the Logset sits behind the two

metal tabs on the front edge of the Burner Pan.

It is important that the rear of the logset be positioned

against the rear of the firebox. Due to variance in size with
each Logset the front edge of your Logset may not touch the
upright section of the front tabs.

Ensure that the Logset is sitting flat on the rear tabs on the

Burner Pan (Air Shield for NG owners) by gently pushing down
on the rear of the logset and making sure it is not hung up on the
sides of the Firebox.

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ 14

-------------------------------------------------------------------------------------------------------------------------------------------------------------

Assembling the Fireplace

Illustration 9.3  

The glass front

is held in place by four spring-
loaded clips. To release the
clips, pull and twist.

Gas Manifold

Illustration 9.4  

The burner pan fits

in the base of the Fireplace as
illustrated. On Natural Gas models
an air shield is installed over the
burner.

Illustration 9.5  

These connections

should be checked carefully.

10.  ASSEMBLING THE FIREPLACE

Illustration 10.1  

Place the logset

against the back wall of the
firebox. Center the logset from
side to side. The logset air shield
is located between the ceramic
logset and the burner on natural
gas models only.

logset air shield (NG only)

Illustration 9.2

Gas Pilot Tube

Thermopile Connector

Thermocouple

Connector

To Igniter Button

Piezo

Wire

Содержание Franklin 206

Страница 1: ... appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Franklin Gas Fireplace Model 206 Silo Photo To Come CERTIFIED TO AMERICAN NATIONAL STANDARD Z21 88b 1...

Страница 2: ... conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z233 1 The Franklin Gas Fireplace must be vented with approved direct vent pipe Direct Vent pipe has two concentric passageways which draw outside air in for combustion and let exhaust gasses out Installation or replacement of gas piping the gas Fireplace and repair or servicing of equipment shall be pe...

Страница 3: ...aff Woodstock Soapstone Co Inc 1 Table Of Contents QUESTIONS 800 866 4344 9 00 AM to 5 00 PM Eastern Time Monday Saturday WARNING This unit must be installed by a qualified gas technician in accordance with local codes or in the absence of local codes with the most current edition of the National Fuel Gas Code ANSI Z223 1 NFPA 54 TO THE INSTALLING TECHNICIAN TABLE OF CONTENTS Section Page 1 Code A...

Страница 4: ...essure LPG 13 0 w c Maximum inlet supply pressure NG 11 0 w c Input Btu Hr LPG Max 33 883 0 2 000 ft Min 26 511 NG Max 34 314 Min 22 523 Output Btu Hr LPG Max 26 280 Min 20 561 NG Max 25 876 Min 16 985 Orifice size LPG Sea level to 3000 51 3001 to 7000 53 7001 or more 54 Orifice size NG Sea level to 2000 36 2001 to 3000 37 3001 to 4000 38 4001 to 5000 39 5001 to 6000 40 6001 to 7000 41 7001 to 800...

Страница 5: ... time see illustration 4 1 Approved venting materials are available from Simpson Dura Vent Dealers or direct from Woodstock Soapstone Company Approved components are listed below Dura Vent No Description Galvanized Black Standard Direct Vent Kit consists of 2 65 8 x 2 Straight Pipe 904 904B 1 65 8 x 11 14 Adjustable Pipe 911 911B 2 65 8 x 90 Degree Swivel Elbow 990G 990BG 1 65 8 Wall Thimble 942 1...

Страница 6: ...ce is approved for venting in five configurations 1 Up vertically as much as 20 and then elbow through an outside wall with a maximum horizontal run of 4 2 Straight out the back through an outside wall and into a snorkel termination cap maximum 4 horizontal run with 1 4 rise per foot of run 3 Up vertically through the roof with maximum rise of 24 4 Into an existing fireplace and chimney maximum he...

Страница 7: ...pth 43 5 Min Alcove width Alcove Installation The Franklin Gas Fireplace is approved for installation in an alcove constructed of combustible materials Minimum Clearances for Alcove Installation Min Clearance from back of pipe to wall 2 Min Clearance from Fireplace to side walls 8 2 8 8 The surface of the Franklin Gas Fireplace is hot when the appliance is in use A safe installation requires that ...

Страница 8: ... Direct Vent Flue Systems The Franklin Gas Fireplace is designed to be installed in the following configurations 6 Approved Venting Chimney Configurations Combustible Ceiling in Alcove Installation 56 Min 84 Minimum Clearances to Ceilings in Alcove Installation Min Clearance from top of pipe to ceiling mantle 6 Illustration 5 4 Minimum Clearances to Ceiling in Alcove Installation 6 Min 6 APPROVED ...

Страница 9: ...n See illustrations on page 12 4 Vinyl Siding requires protection from vented heat above the termination Use Simpson Dura vent Vinyl Siding Heat Shield Kit part 950 The venting should be located so that people cannot be burned by accidentally touching hot vent surfaces while the Fireplace is in operation The vent termination must be placed so that it cannot be damaged by automobile doors lawnmower...

Страница 10: ...termination must not be recessed into the the exterior wall or siding 4 Vinyl Siding requires protection from vented heat above the termination Use Simpson Dura vent Vinyl Siding Heat Shield Kit part 950 The venting should be located so that people cannot be burned by accidentally touching hot vent surfaces while the Fireplace is in operation The vent termination must be placed so that it cannot b...

Страница 11: ...em ALL VENT CLEARANCES MUST BE MAINTAINED CHECK YOUR VENT CLEARANCES AGAINST THE ILLUSTRATIONS AT RIGHT AND CHART ABOVE MINIMUM AND MAXIMUM DISTANCES Maximum vertical rise 24 Optional 11 2 restrictor ring at the elbow in the Fireplace Height of termination above roof must conform to chart below Roof Pitch A Minimum height from roof to lowest discharge opening Flat to 6 12 1 0 feet 6 12 to 8 12 2 0...

Страница 12: ...t will carry the exhaust gases to the top of the chimney The surrounding chimney area is utilized to bring fresh air into the stove for combustion Venting into a masonry chimney requires a conversion kit 4 duct and a cap See illustration 6 7 on page 11 Venting into an existing prefabricated metal chimney requires a conversion kit specific to the brand of chimney installed a 4 duct and a cap See il...

Страница 13: ...urely bolted to the floor with steel straps secured to the leg bolts and to the floor with minimum 1 4 lag bolts Contact Woodstock Soapstone Company for steel straps 2 The appliance must be grounded to the manufactured home trailer frame with a No 8 minimum solid conductor ALL VENT CLEARANCES MUST BE MAINTAINED CHECK YOUR VENT CLEARANCES AGAINST THE ILLUSTRATIONS ON PAGE 9 MINIMUM AND MAXIMUM DIST...

Страница 14: ...r deck porch veranda or balcony 12 D Clearance to non mechanical air supply inlet or combustion air inlet of any other appliance 12 E Clearance to inside corner or adjacent wall 12 F Clearance to a non ventilated soffit 12 G Clearance below deck porch veranda or balcony if completely open on two sides 18 H Clearance to ventilated soffit located above the terminal within a vertical distance of 2 fe...

Страница 15: ...r other obstruction at the back of the Fireplace 2 Check that the gas manifold is connected to both the controller and the orifice at the back wall of the Fireplace see illustration 9 1 3 Remove the Front Casting see illustration 9 1 4 Remove the foam wedges used to keep the Pressure Relief Lids in place see illustration 9 2 5 Remove the Glass Front see illustration 9 3 6 Check that the Pressure r...

Страница 16: ...e of the Burner Pan It is important that the rear of the logset be positioned against the rear of the firebox Due to variance in size with each Logset the front edge of your Logset may not touch the upright section of the front tabs Ensure that the Logset is sitting flat on the rear tabs on the Burner Pan Air Shield for NG owners by gently pushing down on the rear of the logset and making sure it ...

Страница 17: ...y line is connected to the Fireplace gas control valve using a 3 8 male NPT fitting If local codes permit it we recommend using a flexible connector as that can alleviate mechanical load on the control valve The gas supply line for either propane LPG or natural gas NG should be large enough to support 34 000 Btu Consult local building codes to properly size the gas supply line 3 TEST FOR LEAKS Tes...

Страница 18: ...etting into the mix If the flame turns orange or smoky then there is too little air getting into the mix To adjust the amount of air Note Allow Fireplace to cool before handling a Remove the Front casting see illustration 9 1 b Remove the Glass Front see illustration 9 3 c Carefully lift and remove the Logset d Remove the Glass Window Retainer by removing the two screws and then remove the single ...

Отзывы: