SETTING UP YOUR STOVE

Your Model  211 Absolute Steel Hybrid woodstove has been shipped assembled except for two parts: 

1) 

The flue collar and cover plate, including the internal cover plate shield. 

2)

Required bottom heat shield.

All necessary hardware and instructions are also  packed in the firebox. Any optional items such as heat shields will be

packed separately.

1)

How to attach the Absolute Steel Hybrid flue collar & cover plate, and the cover

plate shield:

The Absolute Steel Hybrid is designed to be vented out the top or out the rear with an

easily convertible flue collar and cover plate. Each part is secure to the stove body with 4

bolts. You will need a 7/16” wrench or socket and ratchet to install these parts. The stove

is shipped with the cover plate installed over the rear flue exit with an internally mounted

heat shield. The flue collar is packed inside the firebox.

1. Decide which way you would like to vent your stove. This may be dependent on

the location of an existing chimney or the design of an existing hearth. Always pay

close attention to required clearances when considering stove placement

TOP VENTING:

1. If you are 

top venting

, use the (4) bolts supplied making sure that the gasket on it

is secure and stays in place while installing. Use four of the bolts to attach the flue

collar to the stove body. The holes in the stove body are threaded to accept the

bolts. Alternate between the bolts while tightening to ensure even pressure. The

bolts should be tight enough to firmly compress the gasket. Do not over tighten.

REAR VENTING:

1. If you are 

rear venting

, the cover plate has an internally mounted stainless steel heat shield. Two of the four

mounting bolts are longer to accommodate this shield and are diagonally opposite each other. Remove the (2) hex

nuts from these longer bolts using a 7/16” wrench or socket. Remove the shield and set the shield and nuts aside

for reuse.

2.   Remove the (4) mounting bolts from the cover plate and transfer the cover plate to the top of the stove. Install the

(2) longer bolts diagonally opposite from each other (doesn’t matter which 2 holes). Working through the back flue

opening, reinstall the heat shield and snug it down with the (2) nuts. Install the remaining shorter (2) bolts. 

3.   You can now install the flue collar on the rear of the stove using the (4) 1/4-20 hex bolts supplied.

2)

Installation of the required bottom heat shield:

The Absolute Steel Hybrid was tested and listed with the use of the bottom heat shield. The bottom heat shield MUST

be installed prior to lighting the first fire. The attachment instructions can be used for both the ash pan and non-ash pan

versions of the Absolute Steel Hybrid. If your stove DOES NOT have an ash pan, the shield will be flat sheet metal

instead of formed sheet metal.

1. Locate the (4) 1/4-20 studs welded to the bottom of the stove. The studs

can be found in each corner, just behind each leg. With the attachment

flanges facing up, slide the heat shield under the stove centered on the

ash pan housing. The shield is symmetrical so there is no front or back.

2.  Each attachment flange has (2) holes, one on each end. Align these holes

with the studs and push the shield up over the studs. It may be easier to

have a helper during this step.

3. Thread (1) 1/4-20 nut on each stud. 2-3 threads is all that’s necessary as

you want the shield to drop down and rest on the nuts, this will leave a

small air gap. DO NOT affix the shield firmly to the bottom of the stove. 

Image above shows a top mounted

flue collar and rear cover plate

Содержание 211 Navajo Hybrid

Страница 1: ...tringent but they should be followed They were designed to protect you your home and the environment Improper installations are a major cause of serious fires Failure to follow instructions may result in property damage bodily injury or death Before installing a woodstove check your local building codes and any requirements established by your insurance company You may need a local building permit...

Страница 2: ...ld not be less than the flue collar size Note For flues that exceed the recommended area a stainless steel chimney liner is recommended Height Requirements The chimney must extend 3 ft above the point where it passes through the roof and must also be 2 ft higher than any roof surface or obstruction within 10 feet measured horizontally of the chimney You should check your local building codes for a...

Страница 3: ...nimum 5 8 thick clay liner should be cemented in place and run from the outer surface of the brick to the inner surface of the chimney See Diagram B Above C There are also UL Listed kits available that are specifically designed for passing through a combustible wall For more information on these kits please contact Woodstock Soapstone Company Please note there are several UL listed wall pass throu...

Страница 4: ...n 2 Pitched Cathedral Ceiling through the roof Determine where the stove will be placed Be sure all clearance requirements are satisfied Choose the appropriate support for your installation support box or roof support Use a plumb line to locate the support in the ceiling above Cut the appro priate sized hole in the ceiling and install the necessary framing to secure the sup port Install the suppor...

Страница 5: ... circulate into the room The preferred method for installing a stove in front of a fireplace is by running a stainless steel flex liner down the chimney connecting it to the stove at the fire place Chimneys with large flues should be relined to achieve proper draft If the chimney does not have flue tiles or if the tiles are cracked or compromised an addi tional insulating material must be used It ...

Страница 6: ...in terms of R value K value or C value To convert K or C value to R value use the following formulas K to R R 1 K x T Thickness of the alternate material C to R R 1 C Once alternate materials have been converted to R values the values of multiple layers can be added to determine the combined protection If the overall R value meets or exceeds the specified 39 then the materials are acceptable DO NO...

Страница 7: ... Rear Heat Shield Pipe Shield A 18 x 1 414 12 25 22 5 6 A 66 2 WALL PROTECTION The Model 211 Absolute Steel Hybrid stove has been tested to UL stan dards for clearances to combustible walls The minimum clearances to unprotected walls are as follows Minimum clearances with no heat shields to unprotected combustible walls From the back 14 From the sides 26 DO NOT ASSUME THAT A WALL IS NOT COMBUSTIBL...

Страница 8: ...excess heat from being radiated from the pipe Heat shield protection is only required for the first 24 of vertical connector pipe At least 30 is required from the front of the stove to combustibles such as curtains wall hangings and furniture The same clearances from your stove and stove pipe apply to both fireplace and freestanding installations Be particularly careful to check clearances to a wo...

Страница 9: ... to wall 35 5 C Above pipe to ceiling 18 1 Parallel Installation Single Wall Pipe Top Vent A E E D D NO HEAT SHIELD A Back of stove to wall 23 5 D Side of stove to wall 26 B Back of pipe to wall 15 5 E Side of pipe to wall 35 5 C Above pipe to ceiling 18 WITH REAR SHIELD PIPE SHIELD ATTACHED A Back of stove shield to wall 18 D Side of stove to wall 26 B Back of pipe shield to wall 10 E Side of pip...

Страница 10: ...pproved Double Wall Connector Pipe C Pipe to corner 17 min Approved Double Wall Connector Pipe 4 Corner Installation Double Wall Pipe Back Vent C TOP VENT Your stove comes with a rear heat shield attached Do not remove the rear heat shield it provides extra protection in corner installations and also allows for installa tion closer to combustible walls than would would be possible with no shield W...

Страница 11: ...Having outside air for combus tion is a requirement for all woodburning stoves in the state of Washington and is recommended for woodstoves in super tight new construction Tie Downs The stove must be attached to the floor This is to prevent tipping in the event the home is moved We can provide tie downs for our stoves at no extra charge Spark Arrestor The chimney cap must have a spark arrestor scr...

Страница 12: ... the four mounting bolts are longer to accommodate this shield and are diagonally opposite each other Remove the 2 hex nuts from these longer bolts using a 7 16 wrench or socket Remove the shield and set the shield and nuts aside for reuse 2 Remove the 4 mounting bolts from the cover plate and transfer the cover plate to the top of the stove Install the 2 longer bolts diagonally opposite from each...

Отзывы: