Performing Inspections and Tests
• Follow the “I
” on page 30 and “T
•
Examine air filters regularly
and service when needed.
Service the 2 air filters whenever a bowl contains
liquid or other contaminates, or an element
appears dirty (see “A
IR
F
ILTER
M
AINTENANCE
” in
SERVICE MANUAL
).
•
Make sure
notification
buzzer can be
heard over noise
at operator
position.
Make sure the notification buzzer is clearly
audible at the maximum distance between the
operator and the lifter, despite any barriers or
obstacles.
1,
2
Checking the 12-Volt Battery
Always check battery
energy before every lift.
While the lifter is powered up, a battery gauge on the LCD
screen displays the current energy level.
3, 4
• If battery energy is in the red range, discontinue lifter
use and charge the battery (see “12-V
• If battery energy continues to decrease and you try to
attach the lifter to a load, the notification buzzer will
sound continuously and the LCD screen will display “Lockout (low 12V battery)”, along
with a diagnostic code (see “I
” on page 38). In this case, you
must charge the battery in order to continue using the lifter.
1..... Maximum buzzer volume is 95 dBA at 2' [60 cm]. If CE Standards apply, consult EN 7731 to make sure the notification buzzer is compliant.
2..... The “Vacuum Test” on page 32 provides a convenient opportunity to check this.
3..... If the lifter remains in “Power Save” mode for a long time, the pump will run periodically to test the battery.
4..... If the battery charger is connected to an AC power source, the reading on the battery gauge will not be accurate and “Replace 12V battery” may
appear on the LCD screen, because the system cannot accurately evaluate the battery.
OPERATION
Содержание MRTALPCH610CDC3O
Страница 2: ...MRTALPCH6 DC3 RC 35125 Rev 1 0 12 19 2 ...
Страница 6: ...MRTALPCH6 DC3 RC 35125 Rev 1 0 12 19 4 Note A standard MRTALPCH611LDC3 is shown SPECIFICATIONS ...
Страница 11: ...Rev 1 0 12 19 MRTALPCH6 DC3 RC 35125 9 TO CHANGE THE PAD FRAME CONFIGURATION ASSEMBLY ...
Страница 46: ...Rev 1 0 12 19 MRTALPCH6 DC3 RC 35125 45 ...
Страница 47: ...MRTALPCH6 DC3 RC 35125 Rev 1 0 12 19 46 ...
Страница 48: ......