background image

Operating instructions

GB

TROUBLE SHOOTING

If you are having trouble with your dehumidifier, please refer to below trouble shooting

Trouble

Cause

Solution

Machine doesn’t work

Power

 

cord

 

isn’t

 

connected

Connect the unit to a power source

Room

 

temperature

 

over

 

35°C

 

or

 

below

 

0°C

Increase or decrease the

temperature

Cannot start on the dehumidifier

Filter mesh jammed?

Clean

 

the filter

 

mesh

 

according

 

to

 

the

 

manual

Air

 

inlet

 

or

 

outlet

 

jammed?

Clear

 

the

 

blockage

 

from

 

air

 

inlet

 

or

 

air

 

outlet

No

 

air

 

inlet

Filter

 

mesh

 

jammed?

Clean

 

the

 

filter

 

mesh

 

according

 

to

 

the

 

manual

Unormal

 

noise

Is the machine

 

inclined?

Move

 

to

 

flat

 

and

 

firm

 

ground

Filter

 

mesh

 

jammed?

Clean

 

the

 

filter

 

mesh

Trouble

 

code

:

E1

When

 

LED

 

shows

 

E1

there

 

is

 

hu-

midity

 

sensor

 

trouble

 

or

 

humidity

 

sensor

 

connection

 

wire

 

isn’t

 

fixed

.

Change

 

the

 

humidity

 

sensor

 

or

 

check

 

the

 

connection

 

wire

.

Trouble

 

code

:

E2

When

 

the

 

LED

 

shows

 

E2

 

for

 a 

longer

 

period

there

 

is

 

a

 

problem

 

with

 

the

 

water

 

pump

.

Change

 

or

 

repair

 

the

 

water

 

pump

Trouble

 

code

LED flashing

When

 

the

 

LED

 

is

 

flashing

 

in

 

red

there

 

is

 

temperature

 

sensor

 

trou-

ble

 

or

 

connection

 

wire

 

isn’t

 

fixed

.

Change

 

the

 

temperature

 

sensor

 

or

 

check the

 

connection

 

wire

.

Max. working area 

 

280 m²

Recommended working area         

10-190 m²

Air flow      

450 m³/h

Capacity at 10ºC & 60% RH   

10 litres

Capacity at 20ºC & 70% RH   

26 litres

Capacity at 35ºC & 80% RH   

75 litres

Power at 10°C & 60% RH 

390W

Power at 20°C & 70% RH 

500W

Power at 35ºC & 80% RH     

830 W

Working interval temperature         

+0 to +35ºC

Fan speeds             

 

1

Dims LxWxH             

620x410x480 mm

Weight                 

 

35,5 kg

Cooling media, freon free         

R410A

IP rating              

IP22 (X2)

Technical data

Содержание DSC-70E

Страница 1: ...DEHUMIDIFIER Users manual Wood s DSC 70E GB S Operating instructions Bruksanvisning Please read this manual carefully before installing and save the manual for future reference and product warranty...

Страница 2: ...since mites and other creatures thrive in a damp environment A dehumid ifier with high performance creates a good healthy humidity level and for greatest efficiency the doors and windows of rooms tha...

Страница 3: ...le or dangerous goods 4 Do not put fingers or other objects into air inlet or air outlet 5 Do not stand on the machine 6 Please drain water according to the instructions 7 Do not use this machine in a...

Страница 4: ...lluminates in green In continuous mode the unit will defrost automatically and no values can be set manually Press the Add and Minus key again to exit continuous working mode 5 Manual drainage key Opt...

Страница 5: ...be repaired before the unit can be used DRAINAGE PIPE CONNECTION The water pipe is 6 5 meters long and 10mm thick Connect one end of the pipe to the dehumidifier and lead the other end to a drain If t...

Страница 6: ...dirty loosen in by rotating the frame Clean the frame in water Avoid using strong cleaners or solvents as this may damage the frame DEHUMIDIFIER STORAGE If the product isn t used for a long time pleas...

Страница 7: ...ode E1 When LED shows E1 there is hu midity sensor trouble or humidity sensor connection wire isn t fixed Change the humidity sensor or check the connection wire Trouble code E2 When the LED shows E2...

Страница 8: ...n s dan milj kan leda till sjukdomar hos dem som bor i huset d bl a kvalster trivs i en fuktig milj En avfuktare med h g prestanda skapar en bra och h l sosam fuktighetsniv och f r att n b sta effekt...

Страница 9: ...grar eller andra objekt i luftutbl set eller luftintaget 5 St inte p maskinen 6 F lj instruktionerna f r vattenavledningen 7 Anv nd inte maskinen i tillslutna rum 8 Om avfuktaren inte har n gon pump b...

Страница 10: ...Lampan lyser gr nt och avfuktaren kommer att arbeta kontinuerligt tills den st ngs av I kontinuerligt l ge avfrostar maskinen automatiskt och du kan inte st lla in nskad luftfuktighet Tryck p pil upp...

Страница 11: ...2 och avfuktaren kan inte anv ndas f rr n problemet r tg rdat SLANGANSLUTNING Slangen r 6 5 m l ng och 10 mm tjock Anslut slangen till avfuktaren och f r den andra nden till ett avlopp Av loppet kan i...

Страница 12: ...smutsigt lossa den genom att f rsiktigt vrida p ramen Reng r ramen med vatten Undvik att anv nda l sningsmedel eller starka reng ringsmedel d det kan skada ramen F RVARING Om du inte kommer anv nda a...

Страница 13: ...eller s r den inte korrekt inkopplad Byt ut fuktighetssensorn eller kon trollera att den r korrekt inkop plad Felkod E2 N r displayen visar E2 r det prob lem med vattenpumpen Byt ut eller reparera vat...

Страница 14: ...Contact Wood s is marketed and distributed by TES Scandinavia AB Kroksl tts fabriker 30 431 37 M lndal Sweden 46 0 31 761 36 10 www woodseurope com info woods se...

Отзывы: