![Woodfire EX 12 Double Sided Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/woodfire/ex-12-double-sided/ex-12-double-sided_operation-and-installation-manual_994873021.webp)
20|
P a g e
• Has too much wood been loaded into the firebox?
• Was the air supply control set correctly and the supply of combustion air reduced?
The overheat safety valve is constantly running water
• The thermal store has reached its maximum temperature but the stove is still burning its fuel
load. Use heat from the store to lower its temperature and dampen down the stove.
• Check the function and setting of the pump control and the load valve.
• Is the circulation pump running?
• Vent the boiler and check the system pressure.
Noises in the heat exchanger / air in the heating system
• Vent the stove and check the system pressure. When refilling, multiple venting operations may
be necessary. Repeat the venting after a few days.
The overheat safety valve drain is dripping
• Rinse the thermal safety valve by pressing the red head on the valve.
• Check the seat of the connection seals and the piston (see instructions for the overheat safety
valve).
• Add a filter in the cold water inlet in front of the overheat safety valve.
The radiators stay cold
• The heating system takes time to pass the heat to the radiators.
• Has the heating system been balanced?
• Check that the circulation pump is working.
The combustion chamber lining is black
• Check the combustion chamber, the baffle deflectors and the chimney for blockages.
•
The moisture content of the wood is too high. Only use wood with a moisture content of 20% or
less.
• Check that the stove is receiving sufficient combustion air.
Содержание EX 12 Double Sided
Страница 24: ...23 P a g e Woodfire EX Manual Rev 1 0 Technical Details ...
Страница 25: ...24 P a g e Technical Details ...
Страница 26: ...25 P a g e Woodfire EX Manual Rev 1 0 Technical Details ...
Страница 27: ...www woodfirestoves co uk ...