4.1.2 Stove controls
Combustion air completely open (1st fig.)
When lighting and refuelling the lever is pushed to the far right. As a result, the maximum volume
of combustion air is supplied through the grate to the combustion chamber.
Combustion air throttled (2nd fig.)
This is the normal setting during burning.
With the lever in the middle position the combustion chamber only receives secondary air.
The fire burns at a moderate rate. The secondary air flows through the combustion chamber,
giving a clean and efficient burn. The lever may need to be set slightly more to the right or the left
depending on the weather conditions and chimney draught to achieve the optimum combustion.
Combustion air closed (3rd fig.)
With the control lever in the left position no air is supplied to the combustion chamber. The air
supply must not be closed until the fuel has burned out completely. If the stove is not in
operation, always close the air supply.