temperature of 60°C is essential to ensure the stove burns cleanly and efficiently. The maximum
operating temperature is 90°C. The maximum operating pressure may not exceed 2.5 bar.
A minimum pipe size of 28 mm should be employed up to and back from the load unit. If there is a
heat leak radiator in the circuit then a minimum pipe size of 28mm should be used on the flow and
return from that radiator to facilitate thermosyphoning.
Pay attention to a correct design of all components in the heating system.
The operator must be instructed in the operation, functioning and maintenance of the entire
system including any additional specialist components.
To realise the full potential of a heating and hot water system run by a Woodfire boiler stove it is
important to have an accumulator (buffer) tank in the system.
At the lowest points of the heating system an outlet valve needs to be installed.
The figure below is a typical plumbing schematic showing the boiler stove connected to a thermal
store. The positioning of the pipes for the heat leak radiator around the load unit is very
important. In the LK 810 ThermoMat range, the gravity circuit flap grub screw should be removed
to allow circulation around the heat leak radiator in the event of power failure.