![WoodFast M320 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/woodfast/m320/m320_instruction-manual_994857007.webp)
To avoid electrocution or fire, any maintenance or repair to electrical system should be done only by qualified electricians
using genuine replacement parts.
WARNING
3.3 ELECTRICAL CONNECTION
- Electrical installation should be carried out by competent, qualified personnel.
- The mains connection should be made using the terminal box.
- Replacement of the power supply cable should only be done by a qualified electrician.
3.4 NOISE LEVEL
No load Load
Sound Pressure Level < 80dB(A) < 90dB(A)
Sound Power Level < 90dB(A) < 100dB(A)
The noise levels measured are emission levels and not necessarily the safe working level. Although there is a
correlation between the emission levels and the exposure levels, this cannot be used reliably to determine whether or
not further precautions are required. The factors which affect the actual level of operator exposure include the duration
of exposure, the ambient characteristics and other sources of emission, for example, the number of machines and
other adjacent machining. The permitted exposure values may also vary from country to country. Nevertheless, this
information allows the user of the machine to better evaluate the dangers and risks.
Other factors which reduce exposure to noise are:
- correct tool choice
- tool and machine maintenance
- use of hearing protection systems (e.g. headsets, earplugs,...)
WARNING
Please use the hearing protection systems if the above mentioned noise levels
exceed 95dB(A).
-7-
POWER CABLE
MOTOR CABLE
YELLOW
GREEN
WIRE CAP
YELLOW
GREEN
WHITE
BLACK
BLOWN
M+
X3
MOTOR
M-
X4
BLUE
BLOWN
BLUE
OUT
IN
CN8
CN9
CN3
CN7
ROTATION
CONTROL
CABLE
DIGITAL
READOUT
CABLE
SESOR
CABLE
POTENTIONMETER
CABLE
Содержание M320