CHECKING GAS PRESSURE
27
Install and attach
1
/
2
" gas line onto shut-off valve.
Figure 34 - Gas Pressure Check at Gas Valve
Pressure Test
“IN”
Pressure Test
“OUT”
HI/LO
Knob
Pilot Adjustment
Screw
Do not use open flame to check for gas leaks.
WARNING
Control knob
Ignitor
STOP! Do not install theappliance. Contact your dealer immediately.
2. To ease installation, a
48
"
x1/2"
flex line with manual shut-off
valve has been provided with this appliance.
1. Check gas type. The gas supply must be the same as stated on the
appliance’s rating decal. If the gas supplyis different from the fireplace,
3. After completing gas line connection, purge air fromgas line
and test all gas joints from the gas meter to thefireplace for leaks.
Use a solution of 50/50 water andsoap or a gas sniffer.
4. To adjust flame height, turn HI/LO knob to HI to getmaximum
pressure to burner. Turn HI/LO knob to LO to get minimum
pressure.
5. To check gas pressures at valve, turn captured screwcounter
clockwise 2 or 3 turns and then place tubingto pressure gauge
over test point. Turn unit to high.
See Figure 34.
After taking
pressure reading, be sure and turn captured screw clockwise firmly
to reseal. Do not overtorque. Check test points for gas leaks.
6. The appliance and its appliance main gas valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 psi
(3.5 kPa). The appliance must be isolated from the gas supply
piping system by closing its equipment shutoff valve during any
pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psi (3.5 kPa).
ELECTRICAL INSTALLATION
ELECTRICAL WIRING
This fireplace will work without any electrical supply. Electricity is only needed to operate blower.
NOTE: If installed in mobile home, fireplace must be bolted securely to floor.
WARNING
Verify proper operation after servicing.
CAUTION
Label all wires before disconnecting when servicing controls.
Wiring errors can cause improper and dangerous operation.
Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off
when connecting to main electrical power supply or performing service. All wiring shall be in compliance
with all local, city, and state codes. The appliance, when installed, must be electrically grounded in
accordance with local codes, or in the absence of local codes, with the
National Electrical Code ANSI/
NFPA 70 (latest edition)
and
Canadian Electrical Code, CSA C22.1.