 CAUTION 

 DANGER 

IMPORTANT  SAFETY  INSTRUCTIONS

 Indicates that failure to follow the instruction may cause body injury or 
 property damage. 

GROUNDING INSTRUCTIONS

 Improper use of the grounding plug can result in a risk of electric shock. 

SAVE THESE INSTRUCTIONS

1. Do not install or use the product in wet places as steam room etc.This product must be     
    connected to properly grounded power outlet socket.
2. It is recommended to use water-proof electrical outlet which should be lnstalled in the place 
    where is not easily got wet. 
3. This product should be used with AC 110V-120V,50/60Hz electrical current only,load current     
    is at least 15A. P ower plug must be equipped with ground fault circuit interrupter or ground     
    fault electrical leakage protector or similar high sensitive, rapid type leakage switch    
    (Rated sensitive current under 6mA).
4. When it thunders,it is strongly recommended to pull out the power plug.
5. Do not stand on ceramic toilet.
6. Ceramic toilet must install floor fixing bolt.
7. Do not stand on product unit,seat and cover.
8. Do not lean against the seat cover when using the product,to avoid damage.
9. This product is equipped with soft-closing seal cover.Heavy pressing or pushing may damage 
    the soft-closing damper. 
10. Do not use lacquer thinner,petrol,liquid medicine,detergent,insecticide,toilet cleanser and      
    scrubbing brush to clean the product.
11.Exposure to direct sunlight is prohibited.
12.Only use tap water or potable water;otherwise it may cause chafing.
13.Do not connect water supply to heater outlet.Make sure inlet water temperature at 3~35˚C
14.When the room temperature is under zero degree,please dry up the water tank,to avoid 
     freezing. 
15.Raise rest room temperature to prevent the toilet from damage due to freezing.
16.When move the product from cold or wet environment into normal room temperature,wait for     
     2 hours until the condensation water is fully volatilized.Doing so can prevent the product from     
     electrical short-circuit.
17.When not using the product over three(3) days,drain the water out of the container and pull      
     the elelctrical plug from the wall outlet.
18.Stop using the product and shut off the power when product malfunctions,please contact the      
     service people for professional service.

This product should be grounded. In the event of an electrical short circuit, grounding reduces 
the risk of electric shock by providing an escape wire for the electric current. This product is 
equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged
into an outlet that is properly installed and grounded.

If repair or replacement of the cord or plug is necessary, do not connect the grounding wire to
either flat blade terminal. The wire with insulation having an outer surface that is green with or
without yellow stripes is the grounding wire.
This product is factory equipped with a specific electric cord and plug to permit connection to a
proper electric circuit. Make sure that the product is connected to an outlet having the same
configuration as the plug. No adapter should be used with this product. Do not modify the plug
provided — if it will not fit the outlet, have the proper outlet installed by a qualified electrician. If
the product must be reconnected for use on a different type of electric circuit, the reconnection
should be made by qualified service personnel.

Содержание B0970S

Страница 1: ...it available for future maintenance or reference Our company reserves the right of final interpretation for this manual The manual is subject to change without notice Customer Service Phone 562 229 0...

Страница 2: ...e of the product the power plug must be switched off and water supply be shut off WARNING To reduce the risk of burns electrocution fire or injury to persons 1 Close supervision is necessary when this...

Страница 3: ...ature at 3 35 C 14 When the room temperature is under zero degree please dry up the water tank to avoid freezing 15 Raise rest room temperature to prevent the toilet from damage due to freezing 16 Whe...

Страница 4: ...phon device Anti backflow device Filter device Over 0 2m3 min 6 different level adjustment Thermal fuse Temperature senor Thermostat 250W 1400W 3 1 2 1200W 1400W 110V 120V 50 60Hz Spray cleansing loca...

Страница 5: ...bly User ID setting Automatic flushing 6 different level adjustment 50W Quiet soft closing device Auto open and close The seat temperature will automatically lower to level 1 in 10 minutes after using...

Страница 6: ...alve Flange Thank you for choosing our products Please rea the instructions carefully before installation and keep it available for future maintenance or refere Our company reserves the right of nal i...

Страница 7: ...www woodbridgebath com 6 R WOODBRIDGE TECHNICAL DRAWING The product drawing is for reference only and we reserve the right to modify the appearance of the product 27 1 4 16 1 8 15 3 8 18 5 8...

Страница 8: ...bridgebath com Flush Front cleaning button Rear cleaning button Stop Left side PARTS IDENTIFICATION Bumper Seat Ceramic toilet Lid Remote sensing window Drying baffle Rear cleaning Spray nozzle Front...

Страница 9: ...dimension of toilet 1 Installation of mating angle valve Line Drain outlet Mating angle valve 2 Cardboard installation Align cardboard with the centerline of drain outlet Draw contour line according t...

Страница 10: ...ltion Install sealing flange into drain outlet Install ceramic toilet on corresponding position according to contour line Tips The toilet is heavy and it needs to open the seat cover to carry it by tw...

Страница 11: ...tch plug indicator lights on indicating that the power is on Tips Press electric leakage test button prior to usage the reset switch pops up indicating that the leakage protection function is normal E...

Страница 12: ...enance 2 Wipe the stain with a soft damp cloth 3 Safety self inspection After cleaning re connect the toilet with the power supply 3 Use soft cloth or soft brush to clean Do not pull or push the spray...

Страница 13: ...lve nut 2 Remove filter net 3 Use the brush to clean filter net 4 Reinstall filter and angle valve nut turn on the angle valve and connect power then it can work normally after self inspection No wate...

Страница 14: ...to prevent freezing To discharge water 1 Drain out the water inside tank Activate flushing and then turn off angle valve to prevent water inlet 2 Drain out the water inside pipe Unscrew the hose conn...

Страница 15: ...he rear portion of body Press rear cleaning button repeatedly then turn on off mobile massage function Press stop button to stop When one circle cleaning is finished and the body remains seated the dr...

Страница 16: ...rea User doesn t reach the sensing area in seat Deodorization function keeps working after user leaves If the problems cannot be solved as per above methods please shut off the power and contact servi...