TROUBLESHOOTING GUIDE
Problem
Cause
No Water from
Nozzle
Water inlet hose bent to
cause blocking
Inlet valve is off
Water supply is cut off
Weak water
cleaning
cause partial blocking
Inlet valve is not fully
turned on
Inlet filter blocked
The water temperature is setted
on normal temperature level
The seat temperature is setted
on normal temperature level
In standby mode
Solution
Solve the problem of bending
of water inlet hose
Turn on the inlet valve
Connect water supply and
wait for the water
Solve the problem of bending
of water inlet hose
Turn on the inlet valve fully
Clean the filter
Reset the water temperature
Reset the seat temperature
No wind out
Spray wand
cannot retracted
Spray wand
cannot stretch out
display
Malfunction of
deodorization
Caution
The wind temperature is setted
on normal temperature level
In standby mode or power
save mode
Power off
Get stuck by impurities
Power off
Not sit in sensing area
User doesn't reach the
sensing area in seat
Deodorization function
keeps working after user
leaves
If the problems cannot be solved as per above methods, please
shut-off the power, and contact service providers for maintenance.
If the leakage circuit breacker often trips off, it means the
products has electricity leakage, so please shut-off the
power, and contact service provider for maintenance.
It's a normal phenomenon if
deodorization function keeps
working after user leaves to
ensure eliminating smell entirely
Adjust to reach the sensing area
Reload the battery
Sit right in the sensing area
Push back the wand lightly and
wait for the power
Clear away the impurities
Push back the rod lightly and
wait for the power
Shift to function mode to use
dry function
Reset the wind temperature
Low water
temperature
Low seat
temperature
Low wind
temperature
Remote control
cannot
Switch to functional mode and
use it after 3 minutes of use
Water inlet hose bent to
The battery of the remote control
is installed in the opposite direction