ADJUSTMENT & MAINTENANCE (DUAL FLUSH VALVE)
Gasket
Check the dual flush
valve and make sure that
it does not have any
damaged or missing
parts
Install a body of the flush
into the base and make
sure they can be totated
clockwise arbitrarily.
Install the base with the
rubber gasket in the
tank, turn the screw as
illustrated to make sure
there is no water leakage
and no looseness
Full flush and half Flush range
will decline when the button is
moved upward from the bottom
Check the completeness
of the product before
adjustment
Take out the lock nut and
insert the push button
into the tank cover
Adjust the push button
and lock the nut to make
it well-fixed in the tank
The distance between the
rod tail and valve push
button must be 1-2mm
Rotate the valve
clockwise to adjust its
position inside of the
toilet's tank
Install the sealing gasket
Put the refill tube into the
white cap hole firmly
The refill tube can't be lower
than the watersealing level
If the rod is too short, please
re-adjust it (outward
rotation).
If the rod is too long please
cut-off the extra length and
re-adjust it.
1. BASE INSTALLATION
2. FLUSH VOLUME ADJUSTMENT
3. PUSH BUTTON ADJUSTMENT
4. REFILL TUBE ASSEMBLY
TROUBLESHOOTING
Full Flush
Half Flush
RIGHT
WRONG
Water
Level
Important Note: Flush GPF amount is factory set. No addi
ti
onal adjustment is required.
This page is for reference only. All adjustments are already made by manufacturer.