Clearances
Professional Series Grill Installation and Operation Manual
INSTALLATION CLEARANCES
Floor:
For use on only on noncombustible floors (installér sur un plancher incombustible seulement). The Profes-
sional Series Grill must be installed on a non-combustible floor extending 3 ft. in all directions from the appliance
or one provided with a non-combustible covering acceptable to the authority having jurisdiction.
A MAJOR CAUSE OF APPLIANCE RELATED FIRES IS A FAILURE TO MAINTAIN REQUIRED CLEARANCES TO
COMBUSTIBLE MATERIAL. IT IS OF UTMOST IMPORTANCE THAT THIS APPLIANCE BE INSTALLED ONLY IN ACCOR-
DANCE WITH THESE INSTRUCTIONS.
SIDES
ABOVE, if installed
under a suitable
metal hood or
masonry chimney.
The hood or chimney
assembly should
extend at least 12
inches beyond the
outside perimeter of
the grill to ensure
adequate capture of
smoke.
36"
36"
72"
MINIMUM CLEARANCES
TO COMBUSTIBLE
CONSTRUCTION
SIDES, FRONT & BACK: 36"
ABOVE: 72", IF INSTALLED
UNDER A SUITABLE METAL
HOOD OR MASONRY
CHIMNEY. SEE PG. 6 FOR
INSTALLATION IN A ROOFED
AREA.
WARNING:
DO NOT PACK
REQUIRED AIR
SPACE WITH
INSULATION
OR OTHER
MATERIALS.
*
Examples of non-combustible construction include: metal stud wall faced with cement board with a tile or
metal finish; cement block with tile or metal finish.
NON-COMBUSTIBLE
FLOOR
36"
36"
36"
36"
FRONT
BACK
36"
36"