Gas Plancha (GEN1)
Service Manual
PG
46
OF
64
M0102.20 JULY 2019
An ongoing program of product improvement may
require us to change specifications without notice.
WOOD STONE CORPORATION
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
TOLL FREE
800.988.8103
TEL
360.650.1111
FAX
360.650.1166
woodstone-corp.com
IGNITER REMOVAL, v1
REV:
DATE:
PART #:
001-PL4836-4-CT00NG
4/15/2013
bena
DWN BY:
SHEET:
PL4836
4 - Zone Gas Plancha
1
File Location: \\woodstone.net\dfs\CAD\0 Pn\001 Ove
n Main Stations\001-PL_Plancha\Service Manual DFT\P
lancha Gas\4Zone\Revision 1\PL4836-4-CT00NG-1.dft
A
DETAIL A
8 of 13
Igniter Removal Procedure
1.
Disconnect Ignition cable.
2.
Remove pilot igniter gas tube.
3.
Remove 1/4-20 kep nut.
4.
Pull out pilot igniter assembly.
6000-0144-1
Pilot Igniter Gas Tube
9000-0554
1/4-20 Kep Nut
002-PL4836-9
Pilot Igniter Shield
Ignition Cable
Ground Strap
PL-4836
VERSION 1:
PRE JUNE 2013