IGNITER REMOVAL, v2 & 3
File Location: \\woodstone.net\dfs\CAD\Manuals\M0102\Rev 02\0_Service_Manual-1.dft
REV:
DATE:
PART #:
WS-PL-4836-4-CT00NG
5/13/2015
bena
DWN BY:
SHEET:
PL4836
4 - Zone Gas Plancha
2
8 of 13
A
DETAIL A
6000-0144-1
Pilot Igniter Gas Tube
9000-0554
1/4-20 Kep Nut
7000-1361
Ignition Cable
Igniter Removal Procedure
1.
Disconnect Ignition cable.
2.
Remove pilot igniter gas tube
from supply side.
3.
Remove 1/4-20 kep nut.
4.
Pull out pilot igniter assembly.
50PL-1327
Pilot Igniter Shield
Ignitor-Sensor, IR Burner
9000-0114
Screw, Truss Hd, Phillips, 10-32 x 1/4", SS
PL-4836
VERSION 2 & 3:
POST JUNE 2013
7000-0250-10