13
9660 & 11260 Fire Deck Coal-Fired Oven
Installation and Operation Manual
GAS SPECIFICATIONS
An ongoing program of product improvement may require us to change
specifications without notice.
FD-9660-CL, FD-11260-CL,
Revised November 2015. Doc no: M0044.03
or visit
woodstone-corp.com
Wood Stone Corporation
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
Toll Free 800.988.8103
Tel 360.650.1111
Fax 360.650.1166
GAS SPECIFICATIONS
The Fire Deck 9660 and the Fire Deck 11260 are equipped with a 1-inch FNPT gas connection (see SPECFICATIONS section)� Have
a licensed gas installer provide the hook-up and test all fittings and pipe connections for leaks� Use approved gas leak detectors
(soap solutions or equivalent) over and around the fittings and pipe connections�
DO NOT USE A FLAME
to test for leaks!
SV-1 is the gas control valve that operates the underfloor Infrared Burner� SV-2 is the gas control valve that operates the interior
Radiant Flame burner� The burner manifold pressures has been adjusted and tested at the factory� A variety of factors can influence
these pressures, so be sure to test the individual burner manifold pressures and adjust the valves as necessary to achieve the
required pressures�
NOTE:
The gas valves are shipped in the ON position�
Wood Stone recommends that the Fire Deck be equipped with a manual, individual shutoff valve, located between the oven and
the main gas supply, and that this shutoff valve (supplied by others) be left readily accessible� Wood Stone also recommends that
inspection and maintenance of the burners and gas piping connections of this appliance be performed at regularly scheduled
intervals and only by professional gas appliance service agencies�
FACTORY SPECIFIED VALVE OUTLET PRESSURE
IR BURNER (SV-1)
Natural Gas (NG): 3�5" W�C�
Propane (LP): 9" W�C�
RADIANT BURNER (SV-2)
Natural Gas (NG): 5 inches W�C�
Propane (LP): 10 inches W�C�
GAS CODE LIMITATIONS
The installation of this appliance must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code,
ANSI Z223�1 or the Natural Gas Installation Code CAN/CGA-B149�1, as applicable including:
The appliance and its individual shutoff valve (supplied by others) must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psi (3�45 kPa)�
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve (supplied by others)
during any pressure testing of the gas supply piping system at test pressure, equal to or less than 1/2 psi (3�45 kPa)
.