![Wood-mizer LT70-R Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/wood-mizer/lt70-r/lt70-r_safety-operation-maintenance-and-parts-manual_994570026.webp)
Accuset 2 Troubleshooting
Error Messages (DC Only)
2
2-6
ASdoc032519
Accuset 2 Troubleshooting
2.3
Error Messages (DC Only)
See Table 2-6.
Possible causes for display error messages are provided below.
Error
Possible Cause(s)
CHECK TRANSUCER
Defective or loose transducer cable
Defective transducer
MOTOR CURRENT
Excessive current draw on Up/Down motor
caused by mechanical bind in saw head move-
ment or defective up/down assist cylinder
Short in up/down motor wires
VOLTAGE ERROR
Low voltage at the H-bridge or HMI (front
panel)
Weak battery
Over-charging alternator
Loose connections
CHECK BREAKER
OR CABLE
Tripped Up/Down circuit breaker
Defective or loose communication cable (in
cable carrier)
Defective or loose H-bridge communication
(splitter) cable
TABLE 2-6